Campbell CS655 Uživatelský manuál Strana 19

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 34
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 18
Model HFP01SC Self-Calibrating Soil Heat Flux Plate
19: Z=X-Y (P35)
1: 9 X Loc [ work ]
2: 5 Y Loc [ mV_180 ]
3: 9 Z Loc [ work ]
20: Z=ABS(X) (P43)
1: 9 X Loc [ work ]
2: 9 Z Loc [ work ]
21: Z=X/Y (P38)
1: 3 X Loc [ cal ]
2: 9 Y Loc [ work ]
3: 3 Z Loc [ cal ]
22: End (P95)
23: End (P95)
End Program
-Input Locations-
1 shf
2 shf_mV
3 cal
4 mV_0
5 mV_180
6 mV_end
7 V_Rf
8 shf_mV_a
9 work
6.3.3 Example 3. Sample CR23X Program Using a Differential
Measurement Instruction
TABLE 6-5 provides the wiring for Example 3.
TABLE 6-5. Wiring for Example 3
Description Color CR23X
Sensor Signal White 9H
Sensor Signal Reference Green 9L
Shield Clear
Heater Resistor Signal Yellow 10H
Heater Resistor Signal Reference Purple 10L
Shield Clear
Power Red SW12
Power Reference Black G
13
Zobrazit stránku 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 33 34

Komentáře k této Příručce

Žádné komentáře