TX312 Transmitter
TABLE 5.2-7. Error Codes
Error Codes:
Hex Decimal
0x00 00 No error
0x01 01 Illegal command
0x02 02 Command rejected
0x03 03 Illegal checksum or too much data
0x04 04 Time out or too little data
0x05 05 Illegal parameter
0x06 06 Transmit buffer overflow
0x10 16 Message abort due to PLL
0x11 17 Message abort due to GPS
0x12 18 Message abort due to power supply – internal 16 volt – RF
0x13 19 Software fault
0x14 20 Failsafe fault
0x15 21 GPS time sync fault
0x16 22 SWR fault – transmission antenna connection
0x19 25 Internal RF power supply failure
See Section 5.1.2.4 for more information.
5.2.5.6 P127, Command 5: Clear TX312 Error Registers
Clear error registers of TX312. Requires one input location.
TABLE 5.2-8. P127 Command 5: Clear Error Registers
In Loc Contents
1 Result Code
Result code of 0 indicates success. Command 5 is used to erase all errors from
the error registers of the TX312.
5.2.5.7 P127, Command 6: Return TX312 to on-line mode.
Command 6 is used to return the TX312 to online mode. Typically used after
a forced random transmission. The TX312 has an off-line time-out of one
hour.
TABLE 5.2-9. P127 Command 6: Force On-line Mode
In Loc Contents
1 Result code
Result code of 0 indicates success.
5.2.6 Edlog Programming Examples
Edlog instruction 126 is used to copy data from the datalogger final storage
area to the TX312 data buffer.