Campbell AVW200 series Manuál s instrukcemi Strana 1

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Měření, testování a kontrola Campbell AVW200 series. Campbell AVW200 series Instruction manual [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 114
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
INSTRUCTION MANUAL
AVW200-series 2-Channel
Vibrating Wire Spectrum
Analyzer Modules
Revision: 3/15
Copyright © 2008- 2015
Campbell Scientific, Inc.
Zobrazit stránku 0
1 2 3 4 5 6 ... 113 114

Shrnutí obsahu

Strany 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Revision: 3/15 Copyright © 2008- 2015

Strany 2

Table of Contents 5-7. Opening Page of the Troubleshoot Tool... 33 5-8. Options Tab of the Troubleshoot Too

Strany 3 - Limited Warranty

Appendix H. Additional Programming Examples Scan (2,Min,0,0) PanelTemp (PTemp,250) Battery (Batt_volt) AVW200(VWResults(1),ComME,0,20

Strany 4 - Assistance

Appendix H. Additional Programming Examples H.2 Datalogger-Controlled Multiplexer ' 'This example demonstrates how to program a CR1000 to

Strany 5 - Precautions

Appendix H. Additional Programming Examples Sample (16,Sig2Noise2(),FP2) Sample (16,FreqOfNoise2(),FP2) Sample (16,DecayRatio2(),FP2) Sample

Strany 6

Appendix H. Additional Programming Examples 'Gage Factors for sensors attached to AM16/32 #3 Coef3(1) = 2.73949e-10: Coef3(2) = 8.726e-5:

Strany 7 - Table of Contents

Appendix H. Additional Programming Examples PortSet(1,1) 'Enable Mux1 For i = 1 To 16 'Do the following for each of 16 sensors

Strany 8

Appendix H. Additional Programming Examples PortSet(7,1) 'Enable Mux4 For i = 1 To 32 'Do the following for each of 32 sensors:

Strany 9

Appendix H. Additional Programming Examples H-12

Strany 10

Appendix I. Using MD485 Multidrop Modems with AVW200 Interfaces For situations where wireless communication is impractical, MD485 Multidrop Modems m

Strany 11 - 1. Overview

Appendix I. Using MD485 Multidrop Modems with AVW200 Interfaces I.2 Connections The point-to-point configuration is the simplest MD485-to-AVW200 net

Strany 12 - (p. 10))

Appendix I. Using MD485 Multidrop Modems with AVW200 Interfaces FIGURE I-4. MD485 and its connectors. I.2.1 Datalogger to MD485 The 18663 Null

Strany 13 - 1.2 Specifications

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules The AVW200 series consist of a base model (AVW200) and three wireless models (AVW206

Strany 14

Appendix I. Using MD485 Multidrop Modems with AVW200 Interfaces FIGURE I-5. MD485-to-MD485 Connections and Grounding I.2.3 MD485 to AVW200 The 18

Strany 15 - 1.4 Use with Multiplexers

Appendix I. Using MD485 Multidrop Modems with AVW200 Interfaces 'CR1000 Series Datalogger 'This program measures 2 sensors on 2 AVW200s PB

Strany 16

Appendix I. Using MD485 Multidrop Modems with AVW200 Interfaces I-6

Strany 18

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Strany 19

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules The eliminated parameters are: • Number of steps • Number of cycles • Time of Swe

Strany 20 - 2.2 Temperature

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 1.2 Specifications 1.3 Communication 1.3.1 Datalogger The AVW200 module is design

Strany 21 - 3. Quick Start Guides

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 1.3.1.1 PakBus Protocol/Direct RS-232 Connection When using the PakBus protocol, the

Strany 22 - 3.1.2 Wireless Connection

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 1.3.2 Computer 1.3.2.1 Device Configuration Utility The Device Configuration (DevCo

Strany 23

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 1-1. Network of AVW200s and AM16/32Bs (using a direct RS-232 connection) FI

Strany 24 - (p. 25), and Section

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 1-3. Network of AVW200 Interfaces (SDI-12) 2. Measurements 2.1 Vibrating W

Strany 25 - 3.2.2 Wireless Connection

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 2-1. Cutaway of Vibrating Wire Sensor There are three user-determined inpu

Strany 26 - (p. 26))

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules TABLE 2-2. AVW200 Measurement Outputs Output Units Description Resonant Frequency

Strany 28 - 4. Connections

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 2-2. DevConfig plots showing the AVW200 measurement approach. Please note t

Strany 29 - 4.2 Power and Ground

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Read more! You can find an example program that converts resistance to temperature i

Strany 30

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Check the manufacturer’s specification for the sensors frequency and excitation range

Strany 31

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 3. Connect an antenna (or antenna cable with Yagi or omnidirectional antenna attache

Strany 32 - 4.5 Multiplexer Wiring

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 3.2 Multiplexers Controlled by AVW200 3.2.1 Direct RS-232 Connection Cab

Strany 33

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Check the manufacturer’s specification for the sensors frequency and excitation range

Strany 34

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules At the AVW206 site, do the following steps: 1. Use DevConfig to configure the AVW206

Strany 35 - 5.1 Connecting to DevConfig

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules For example, the following AVW200() instructions can be used to control the multiplex

Strany 36 - 5.2 Deployment Tab

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules The following steps are used: 1. Access DevConfig to configure the AVW200 for SDI-12

Strany 37

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 4-1. Wiring for Sensor Connections 4.2 Power and Ground Each AVW200 has a

Strany 38

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Strany 39 - 5.2.2 Measurement

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 4-2. Ground Lug and Power Connectors on the AVW200 4.3 Datalogger W

Strany 40 - 5.3 Data Monitor

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules TABLE 4-2. 17855 or SC110’s DTE Cable Wiring Wire Color of 17855 or SC110’s DTE Cabl

Strany 41

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Wireless communication requires the appropriate spread spectrum radio to be connected

Strany 42 - 5.4 Send OS

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 4-4. Example AM16/32-series to AVW200 Hookup (multiplexers controlled by AVW

Strany 43 - 5.5 Troubleshoot

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 4-5. AM16/32B to AVW200 Hookup (AM16/32Bs controlled by datalogger and usi

Strany 44

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 5. Device Configuration (DevConfig) Utility Our Device Configuration (DevConfig) uti

Strany 45

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 5-1. Opening Page in DevConfig 5. Select the Serial Port matching the COM p

Strany 46 - 5.7 Terminal

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 5-2. Deployment Communications Editor in DevConfig Certain AVW206 settings

Strany 47 - 6. Programming

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Net Address—enter the radio network address that matches all of the RF401 radios and

Strany 48

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 5.2.2 Measurement The Deployment/Measurement Tab is used to configure the SDI-12 Add

Strany 49 - (p. 33)) to

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strany 50

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Multiplexer Type—choose the appropriate multiplexer. The default multiplexer type is

Strany 51 - 6.1.2 Sequential Mode

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Read more! Appendix D lists the fields in the public table and provides a brief desc

Strany 52 - 6.2 SDI-12 Measurements

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 5.4 Send OS For most applications, Campbell Scientific does not anticipate that it w

Strany 53

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 5.5 Troubleshoot The Troubleshoot tool in DevConfig can be used to evaluate the freq

Strany 54 - 6.2.3 Use with Multiplexers

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 5-8. Options Tab of the Troubleshoot Tool 4. Select the AVW200 channel eith

Strany 55 - 7. Example Programs

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules FIGURE 5-9. Graphs for Evaluating Spectral Analysis of a Sensor Check the manufactu

Strany 56

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 5.6 Settings Editor The Settings Editor in DevConfig can also be used to enter the D

Strany 57

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules When using the “Mcmm” terminal command, no other method of measurement should be use

Strany 58

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules the AVW200. If more than one AVW200 is used and the instructions are ran in a sequen

Strany 59

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules multi-dimensioned array of 5 or 6 if multiple sensors are being measured using a mult

Strany 60

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Strany 61 - 7.5 SDI-12 Example

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules BeginFreq The BeginFreq parameter is the starting frequency to use for the vibrating

Strany 62

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 6.1.1 Pipeline Mode When the CRBasic program first starts running, the information s

Strany 63

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules detected. Therefore, the result variable for the first instruction would be zero (in

Strany 64 - 8.3 Wireless Communications

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules SDIPort The SDIPort parameter is the port to which the SDI-12 sensor is connected. A

Strany 65

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules If a check summed command fails, a NAN will be returned and the command will be retri

Strany 66

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 7. Example Programs This section includes several program examples for our CR1000 da

Strany 67 - A.1 Displacement Example

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules CallTable avw200 CallTable avwcard NextScan EndProg 7.1.2 Wireless/On

Strany 68 - Thermistor

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 'Calculate displacement (inches) from Digits and calibration polynomial PS

Strany 69 - B.2 Accuracy and Resolution

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 7.3 AVW200( ) Instruction Running in the Pipeline Mode The following program is an e

Strany 70

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules ' Example Program running in the PipeLine mode ' The clock and reset lines

Strany 72

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules TABLE 7-4 shows the wiring used for both Sequential Mode examples. TABLE 7-4. Wiring

Strany 73 - AVW206, AVW211, and AVW216

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Const Chan1 = 1 ' AVW200 channel 1 Const Chan2 = 2 ' AVW200 chann

Strany 74 - (p. C-6), of this manual

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules very next measurement will use the bbbb,eeee and vvvv values specified in the extende

Strany 75

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules ' Example Program running SDI12 commands with the Datalogger controlling '

Strany 76

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules 8. Troubleshooting Communication Problems 8.1 Unable to Communicate with DevConfig

Strany 77 - C.3 Surge Protectors

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Power supply must be able to sustain at least 9.6 V (datalogger minimum) even durin

Strany 78

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules b. Change to a higher gain antenna c. Change polarization (element orientation) of

Strany 79

Appendix A. Conversion from Hertz The calibration report provided with each vibrating wire sensor contains the information required to convert Hertz

Strany 80

Appendix A. Conversion from Hertz FIGURE A-1. Geokon Calibration Report of a Sensor without a Thermistor A-2

Strany 81 - (p. 32))

Appendix B. Thermistor Information B.1 Converting Resistance to Temperature The AVW200 outputs a resistance value for sensors that contain a thermi

Strany 82

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Strany 83

Appendix B. Thermistor Information 4. Precision of the bridge resistors 5. Accuracy of the datalogger's voltage measurement 6. Temperature coeff

Strany 84

Appendix B. Thermistor Information FIGURE B-2. Temperature Measurement Error on a 1000 foot Lead. Wire is 22 AWG with 16 ohms per 1000 feet. FIGU

Strany 85 - Appendix E. Status Table

Appendix B. Thermistor Information FIGURE B-4. Temperature Measurement Error on a 5000 foot Lead. Wire is 22 AWG with 16 ohms per 1000 feet.

Strany 86

Appendix C. Antennas, Antenna Cables, and Surge Protectors for the AVW206, AVW211, and AVW216 C.1 Antennas Several antennas are offered to satisfy

Strany 87

Appendix C. Antennas, Antenna Cables, and Surge Protectors for the AVW206, AVW211, and AVW216 16005 0 dBd ANTENNA, 2.4 GHz, OMNI ½ WAVE WHIP, RPSMA

Strany 88

Appendix C. Antennas, Antenna Cables, and Surge Protectors for the AVW206, AVW211, and AVW216 ITEM # 14204 900 MHZ OMNI ½ WAVE WHIP 0 dBd ITEM # 1

Strany 89 - Graph Information

Appendix C. Antennas, Antenna Cables, and Surge Protectors for the AVW206, AVW211, and AVW216 ITEM #15970 900 MHZ Indoor OMNI 1 dBd Window/Wall Mo

Strany 90

Appendix C. Antennas, Antenna Cables, and Surge Protectors for the AVW206, AVW211, and AVW216 FIGURE C-2. Example COAX RPSMA-L Cable for Yagi or Om

Strany 91 - F.2 Good Sensors with Noise

Appendix C. Antennas, Antenna Cables, and Surge Protectors for the AVW206, AVW211, and AVW216 • When the antenna cable length exceeds 10 feet • Whe

Strany 92

Appendix C. Antennas, Antenna Cables, and Surge Protectors for the AVW206, AVW211, and AVW216 This device complies with part 15 of the FCC Rules. Op

Strany 93 - Example

Table of Contents 5.4 Send OS ... 32 5.5 Troubleshoot ...

Strany 94

Appendix C. Antennas, Antenna Cables, and Surge Protectors for the AVW206, AVW211, and AVW216 C-8

Strany 95 - Examples

Appendix D. The Public Table The public table of the AVW200 displays the current sensor measurement values as well as the current settings (see TABL

Strany 96

Appendix D. The Public Table Values and Control Parameters for SDI-12 Communications SDI12val(1) Frequency value obtained by SDI Recorder Instructi

Strany 97

Appendix D. The Public Table Control Parameters When Troubleshooter is Running TimeSeries(1) Writing this variable will force a Vibrating Wire measu

Strany 98

Appendix D. The Public Table D.1 Forced Measurement Program SequentialMode Public UsrForcedMsmnt Public SVResult(2), GVResult(2), TimeSeries(1

Strany 99

Appendix E. Status Table The AVW200 status table contains system operating status information accessible via DevConfig, terminal emulator, or anothe

Strany 100

Appendix E. Status Table Status Fieldname Description User can change? Rf_ForceOn When Rf_ForceOn is set to 1 the radio is always on ignoring the

Strany 101

Appendix E. Status Table Status Fieldname Description User can change? MSPClkFreq(3) MSP430 CPU #3 RC oscillator frequecy in Hz No MSPClkFreq(4)

Strany 102

Appendix E. Status Table E-4

Strany 103

Appendix F. Time Series and Spectrum Graph Information The AVW200 uses an audio A/D for capturing the sensor’s signal. The number of samples acquir

Strany 104

Table of Contents D. The Public Table ... D-1 D.1 Forced Measurement Program ...

Strany 105

Appendix F. Time Series and Spectrum Graph Information FIGURE F-1. Good Sensor with a Narrower Range (200 to 2200 Hz) FIGURE F-2. Good Sensor wit

Strany 106

Appendix E. Status Table F.2 Good Sensors with Noise The measurements graphed in FIGURE F-3 and FIGURE F-4 are made by the same sensor used for FIGU

Strany 107 - I.1 Required Settings

Appendix F. Time Series and Spectrum Graph Information FIGURE F-4. Good Sensor with Noise (450 to 6500 Hz) Check the manufactures specification for

Strany 108 - I.2 Connections

Appendix G. CR10X Programming Example Although this example is for the CR10X, the CR23X is programmed similarly. ;{CR10X} ; ; ; *Table 1 Program

Strany 109 - I.2.2 MD485 to MD485

Appendix G. CR10X Programming Example 10: Z=X (P31) ;Write Decay Ratio to inlocs 65-80 1: 95 X Loc [ DcayRatio ] 2: 65 -- Z

Strany 110 - I.3 Programming

Appendix H. Additional Programming Examples H.1 AVW200-Controlled Multiplexer H.1.1 Direct RS-232 Connection 'This is an example of a program

Strany 111

Appendix H. Additional Programming Examples Sample (16,Displacement2(),FP2) Sample (16,VWfreq2(),FP2) Sample (16,Temp2(),FP2) Sample (16,Amp2

Strany 112

Appendix H. Additional Programming Examples 'Assign coeficients listed in CoefString2 to individual variables For i = 1 To 16 SplitStr (Po

Strany 113

Appendix H. Additional Programming Examples H.1.2 Wireless/Sensors with Different Frequencies ' 'This is an example of a program used by a

Strany 114

Appendix H. Additional Programming Examples Sample (16,Displacement2(),FP2) Sample (16,VWfreq2(),FP2) Sample (16,Temp2(),FP2) Sample (16,Amp2

Komentáře k této Příručce