5.4.2 CR10X Example Program
;{CR10X}
*Table 1 Program
01: 5.0000 Execution Interval (seconds)
1: Pulse (P3)
1: 1 Reps
2: 1 Pulse Channel 1
3: 22 Switch Closure, Output Hz
4: 3 Loc [ WS_ms ]
5: 0.799 Multiplier
6: 0.2811 Offset
2: If (X<=>F) (P89)
1: 3 X Loc [ WS_ms ]
2: 1 =
3: 0.2811 F
4: 30 Then Do
3: Z=F x 10^n (P30)
1: 0 F
2: 0 n, Exponent of 10
3: 3 Z Loc [ WS_ms ]
4: End (P95)
5: AC Half Bridge (P5)
1: 1 Reps
2: 25 2500 mV 60 Hz Rejection Range ; 5000 mV(slow/60 hz) for CR23X, 21X
3: 1 SE Channel
4: 1 Excite all reps w/Exchan 1
5: 2500 mV Excitation ; 5000 mV for CR23X, 21X, CR7
6: 4 Loc [ WindDir ]
7: 720 Multiplier
8: 0.0 Offset
6: If (X<=>F) (P89)
1: 4 X Loc [ WindDir ]
2: 3 >=
3: 360 F
4: 30 Then Do
7: Z=F x 10^n (P30)
1: 0 F
2: 0 n, Exponent of 10
3: 4 Z Loc [ WindDir ]
8: End (P95)
9: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
8