Campbell SAT ARGOS Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Software Campbell SAT ARGOS. Campbell SAT ARGOS User manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 394
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
ZENO
®
-3200
User Manual
Version V2.02
June 27, 2003
P/N: 0302116012, Revision C
Michael J. Hart (Software Engineer)
COASTAL ENVIRONMENTAL SYSTEMS, Inc.
820 First Avenue South Seattle, WA 98134
Telephone (206) 682-6048 Fax (206) 682-5658
Web address: http://www.coastalenvironmental.com
Copyright © 2002 by Coastal Environmental Systems, Inc. All rights reserved.
Zobrazit stránku 0
1 2 3 4 5 6 ... 393 394

Shrnutí obsahu

Strany 1 - P/N: 0302116012, Revision C

ZENO®-3200 User Manual Version V2.02 June 27, 2003 P/N: 0302116012, Revision C Michael J. Hart (Software Engineer) COASTAL ENVIRONMENTA

Strany 2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 2 What each sensor is.  When to collect the data from each sensor.

Strany 3 - Table of Contents

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 92Configuring and using the UDP PAD service requires familiarity with

Strany 4

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 93Forwarding a CDPD Packet The cellular modem closes and sends a packe

Strany 5

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 94Type AT+WPNEI=aaa.aaa.aaa.aaa{ENTER} where aaa.aaa.aaa.aaa is the TC

Strany 6

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 95The ZENO®-3200 radio and your host must have good Line of Site (LOS)

Strany 7

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 96Auxiliary Port Pin Pin Function 4 Push-To-Talk (PTT) 9 Audio Transm

Strany 8 - Acknowledgements

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 97is to be used to control radio power in the Power Control Menu. To

Strany 9 - 1. INTRODUCTION

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 98 DIGITAL CONTROL MENU (Cn/m) Change Item n to Value m (E) Save

Strany 10 - 1.3.2. Digital I/O Ports

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 99You may have to send the U{ENTER} command several times to enter the

Strany 11 - 1.3.5. ADC Conversion Rates

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1006.6.7. Data Packetization To ensure that a complete message is sen

Strany 12 - Refer to Section 12.1.4

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 101Use of the Data Collection System is limited to the collection of e

Strany 13 - -3200 BASICS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 3 Frequency inputs: Up to 100 kHz at 0.005% accuracy. 1.3.3. Sensor

Strany 14

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 102Other lines: (757) 824-0125 (757) 824-0156 (757) 824-0126

Strany 15

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 103 > DOWNLOAD MESSAGE_FILE PLATFORM_CE1192D4 BEGIN DOWNLOAD? (Y/N

Strany 16 - -3200 MEMORY

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 104 Figure 6-1. Eastern satellite pointing angles (azimuth: broken li

Strany 17 - 2.3.2. EEPROM

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 105 Figure 6-8. Western satellite pointing angles (azimuth: broken lin

Strany 18 - 2.4. THE USER INTERFACE

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 106The TGT-1 DE-25 port labeled GOES RADIO is connected to the ZENO®-3

Strany 19 - 2.4.2. Online Help

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 107For the Campbell Scientific SAT HDR GOES transmitter, set the COM2

Strany 20 - 32 bit CPU

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 108 If you will be using self-timed transmissions, specify the self-

Strany 21 - -3200 OPERATION

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1096.7.7. Connecting A GOES Radio and Serial Sensors To The Same COM

Strany 22 - Since many ZENO

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 110To define an output message in GOES Binary Format, each field of th

Strany 23

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 111Coastal Environmental Systems uses the Telonics ST-13 ARGOS Platfor

Strany 24

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 4In practice, the best available sample rate is often rather lower tha

Strany 25 - Refer to Section 2.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 112Regional Processing Centers (RPC) are located worldwide in the Unit

Strany 26

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 113 COMMUNICATIONS MENU (Cn/m) Change Item n To Value m (Tn) Termina

Strany 27 - Refer to Section 2.3.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 114With the above communications settings, any regular ZENO®-3200 Data

Strany 28

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 115 Terminal Passthrough Mode: direct communication between two ZENO

Strany 29

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 116 COMMUNICATIONS MENU (Cn/m) Change Item n To Value m (R)

Strany 30

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1176.9.2. SDI-12 Passthrough Mode The SDI-12 Passthrough Mode lets yo

Strany 31

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 118The following example shows how you can use the SDI-12 Passthrough

Strany 32 - Refer to Section 3.1

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 119SYSTEM FUNCTIONS MENU (Cn/m) Change Item n To Value m

Strany 33 - Refer to Section 8.1

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 120 The four ASCII characters whose decimal value range between 28 and

Strany 34 - Discussed in Section 3.2.5

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 121 REPEATER MENU (Cn/m) Change Item n To Value m (U) User M

Strany 35

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 52. ZENO®-3200 BASICS Coastal Environmental Systems ZENO®-3200 User

Strany 36

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1221. The ZENO®-3200 receives a CCSAIL message. 2. The ZENO®-3200 ch

Strany 37

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 123 REPEATER MENU (Cn/m) Change Item n To Value m (U) User M

Strany 38 - Refer to Section 10.3.6

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 124This section describes how to set up the ZENO®-3200 and the speech

Strany 39 - Refer to Section 2.1

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 125 OUTPUT MESSAGE TIMING MENU (Cn/m) Change Item n To Value m

Strany 40

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 126 DATA OUTPUT MENU (Cn/m) Change Item n To Value m (Jn)

Strany 41

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 127 DATA OUTPUT MENU (Cn/m) Change Item n To Value m (Jn)

Strany 42

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 128 MODEM MENU (Cn/m) Change Item n To Value m (Q) Quit (E)

Strany 43

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 129If the speech interface is disabled and modem settings are unchange

Strany 44

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 130 Figure 6-11. Speech interface wiring diagram. 6.12. OPTION

Strany 45 - Refer to Section 10.4.1

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 131The default ZENO®-3200 configuration excludes COM1 and COM2 from th

Strany 46 - 10.4.1

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 6 Figure 2-1. ZENO®-3200 Front Panel Diagram A

Strany 47 - Refer to Section 10.4.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1327. MONITORING & CALIBRATING SENSOR DATA Coastal Environmental

Strany 48

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 133 For sensors that output more than one data value, only the first v

Strany 49

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 134 TEST MENU (Rx,y) Display Sensors x-y RAW Data (Ex) Displ

Strany 50

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1351. Number of times Sensor Record has been called to collect data.

Strany 51

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 136You will need to thoroughly know the links between each Sensor and

Strany 52

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1377.6. DISPLAYING GLOBAL BUILT-IN-TEST (BIT) STATUS The Global Built

Strany 53 - Refer to Section 10.6.4

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1388. ZENO®-3200 ACCESS PRIVILEGES Coastal Environmental Systems Z

Strany 54

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 139 ZENO PROGRAM MENU (S) Sensor Menu (M) Memo

Strany 55

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 140To change either the Administrator Password or the User Password, y

Strany 56

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1419. UPLOADING AND DOWNLOADING AN ENTIRE CONFIGURATION Coastal Envi

Strany 57 - Refer to Section 10.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 72.2. COMMUNICATING WITH AND POWERING UP THE ZENO®-3200 You will need

Strany 58

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 142As with downloading Data Records, you can either download the confi

Strany 59 - 4. RETRIEVING LOGGED

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 143 X-modem Transfer: Enter XT{ENTER} in the System Load Menu. The

Strany 60 - 4.1. DATA RETRIEVAL OPTIONS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 144Type n{ENTER} to not accept deletion of all Data Records, and ZENOS

Strany 61

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 145Option V in the System Load Menu allows you to download your config

Strany 62

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 146Custom versions of ZENOSOFT® are distinguished from standard versio

Strany 63 - Refer to Section 4.1.1

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 14710. ZENO®-3200 CONFIGURATION SPECIFICS Coastal Environmental Sy

Strany 64

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 148configuration changes either to EEPROM or as a file in your compute

Strany 65 - Kermit file transfer

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 149 SENSOR MENU (Cn/m) Change Item n To Value m (Jn) Jump

Strany 66

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 150Appendix D contains a number of sensor configuration examples for c

Strany 67 - Refer to Section 10.6.5

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 151Due to their fine, as opposed to coarse, resolution 18-bit ADC meas

Strany 68 - CCSAIL protocol

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 84. The ZENO®-3200 requires a power source of 10 to16 VDC. You can e

Strany 69

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 152Contact Coastal Environmental Systems if you need an Analog Expansi

Strany 70

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 15318-bit ADC Input voltage range selection Nominal full scale sensor

Strany 71 - 4.6.2. The ZENO

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 154 Simple on/off status  Period of streaming digital pulses  Fr

Strany 72

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 155Sensor Type Code Name Specifics 4 Digital Period Measurement, f

Strany 73

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 156 NMEA 0183: this interface protocol was created by the National M

Strany 74

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 157$HCHDM,342.7,M*2B The value set in the Compass Offset of the System

Strany 75

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 158#00011505<CR><LF>5.65,-24.98,78.2,0,1.2,1A0,51<ETX&g

Strany 76

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 159 Unlike the regular CCSAIL Sensor, no Sensor Input Channel is speci

Strany 77 - SETTINGS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 160atttn<CR><LF> where ttt is the time in seconds required

Strany 78 - -3200 SYSTEM DATE AND TIME

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 161General Serial Script Sensor Specifics (USI) A full explanation of

Strany 79 - 5.5. ZENO

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 92.3.1. RAM Each ZENO®-3200 is shipped with a minimum of 256 kilobyte

Strany 80

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 162Available Port Types Channel (COM Port) Available Port Types COM1

Strany 81 - 5.7. COMPASS SENSOR USAGE

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 163Sensor Type Code (Line Item #1) Name Available Channels (Line Item

Strany 82 - INTERFACES

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 164All SDI-12 and CCSAIL sensors are designed to be used where there i

Strany 83

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 165Coastal Environmental Systems recommends that any communications po

Strany 84

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 166 Sample Interval |---------------------------------------| 20s

Strany 85 - RS232, RS232H, RS485, RS422

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 167Coastal Environmental Systems recommends that the period length of

Strany 86

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 168Count. When the Sensor Sample Count is set to one, only one measur

Strany 87 - 6.3. HARDWARE HANDSHAKING

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 169The ZENO®-3200 conserves power by turning on a switched voltage onl

Strany 88 - -3200 Modem Configuration

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 170The ZENO®-3200 will turn on a switched voltage before the start of

Strany 89

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 171The ZENO®-3200 sets the Excitation Voltage to the value specified i

Strany 90 - ZENOSOFT

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 10Once you are done creating or modifying the configuration, it is rec

Strany 91 - 6.4.2. MODEM SETTINGS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 172If your sensor output is linear192, then coefficient A is always ze

Strany 92

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 173In the case of parabolic (or near-parabolic) sensor outputs, three

Strany 93 - PSTN/PBX

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 174the Zeno Program Menu by typing the command P{ENTER}. A Process Re

Strany 94

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 175Category Number (Line Item #1) Process Category Name Description

Strany 95 - 6.4.3. CABLE PIN-OUTS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 176Process Category Code (Line Item #1) Process Number (Line Item #2)

Strany 96 - 6.5. CELLULAR MODEMS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 177 2 - Add Constant Value 3 - Add Two Data Values 4 - Subtract Tw

Strany 97

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 178The most important resource in knowing which processes you will nee

Strany 98 - CDPD Sierra Wireless MP200

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 17910.4.5. Process Error Checking and Reporting Sometimes, the ZENO®-3

Strany 99

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 180the received value is out of range, bit 2 will be set in the error

Strany 100

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 181The range for any constant is a floating-point number between 3.40

Strany 101

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 11 Changes to process definitions, including addition or deletion of

Strany 102 - 6.6. RADIO COMMUNICATIONS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 182A Data Output Record is an individual data field to be transmitted

Strany 103

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 18310.6.2. Output Message Structure Like the Data Record structures, t

Strany 104

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 18410.6.3. The Different Types of Data Output Records Line Item #1 of

Strany 105

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 185Table of Data Output Record Field Type Codes Field Type Code (Line

Strany 106

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 186Detailed Information about Data Output Field Type Codes Field Type

Strany 107 - 6.6.6. Response Delay Time

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 187Codes #1 or #2. No characters preceding this point in the message

Strany 108 - 6.6.7. Data Packetization

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 188Instead, you need to specify which Data Output Field Type to use to

Strany 109 - 6.7.2. Data Download

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 189The length of the Field Name is limited to ten characters. If you r

Strany 110

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 190 > C1/6 C3/<D><A>SITE<20>1 DATA OUTPUT MENU (

Strany 111

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 191 If you need ARGOS binary data, use Field Type Code #13.  If yo

Strany 113

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 12Sensor Record #1 is the first sensor in the configuration, Sensor Re

Strany 114 - -3200 Configuration

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 192Type of Data Specified In Line Item #4 Recommended Value to Set In

Strany 115

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 193Line Item #7 (the Data Storage Class Code) in each Data Output Reco

Strany 116 - Refer to Section 11.3.3

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 19410.6.7. Creating An Automatic Output Message for CCSAIL Format You

Strany 117 - 6.7.11. GOES Binary Format

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1953. After the first Data Output Record, create another Data Output

Strany 118 - Refer to Section 10.6

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 1966. Create another Data Output Record after the backspace using Dat

Strany 119 - 6.8.3. Data Recovery

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 197data referred to in Line Item #4 (the Input Record) of the Conditio

Strany 120 - 6.8.5. ZENO

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 19810.6.10. Selecting Data To Log & Transmit Via Output Message N

Strany 121

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 199When the Selectable Transmit and Log data field is used, ZENOSOFT®

Strany 122 - 6.9. PASSTHROUGH MODES

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 200 OUTPUT MESSAGE TIMING MENU (Cn/m) Change Item n To Value m

Strany 123

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 201REMEMBER: the ZENO®-3200 will automatically transmit output message

Strany 124 - Refer to Section 6.9.3

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 133. TUTORIAL: BASIC ZENO®-3200 OPERATION Coastal Environmental Syst

Strany 125

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 202Sample Duration is set to 29 minutes and 45 seconds, Output Message

Strany 126

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 203Time :10 :15 :20 :25 :30 :35 :40: 45 :50 :55 :00 :05 :10 :15

Strany 127 - Refer to Appendix A

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 204When you type R{ENTER} in the Zeno Program Menu, the ZENO®-3200 wil

Strany 128 - 6.10. REPEATER CAPABILITY

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 20511. ALARM MESSAGES Coastal Environmental Systems ZENO®-3200 User M

Strany 129 - Refer to Section 5.5

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 206You may configure as many as 4 alarm messages in your ZENO®-3200.

Strany 130

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 207The description of this process in Appendix D, Line Item #5 (the Al

Strany 131

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 208 Use Conditional Start and Conditional Stop Data Output Records (

Strany 132 - 6.11.1. Overview

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 209 You can also configure a single output message to be an alarm mess

Strany 133

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 21011.3.1. Selecting The Communications Port To Transmit The Alarm Mes

Strany 134

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 211You must select the same communications port in the Output Message

Strany 135

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 14After you connect your ZENO®-3200 to your computer and apply power (

Strany 136

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 212A GOES transmitter is limited to transmitting self-timed (regularly

Strany 137 - 6.11.4. Wiring Diagram

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 213REMEMBER: a message to the ARGOS satellite is limited to 32 bytes!

Strany 138 - INTERFACE

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 21412. ADVANCED ZENO®-3200 CONFIGURATION TOPICS Coastal Environmental

Strany 139

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 215 Figure 12.1. ZENO®-3200 Timing Structure Diagram. 12

Strany 140 - CALIBRATING SENSOR

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 216The RTOS is analogous to the Microsoft Windows operating system th

Strany 141 - Refer to Section 10.3.13

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 217Timing is an ever-present parameter that must be taken into account

Strany 142 - Refer to Section 2.4.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 218There are four Sensor Timing Loops. Each Sensor Timing Loop define

Strany 143

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 219It is very important that the time set in the Sensor Timing Loop fo

Strany 144

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 220 The Sample Duration Time must be set to a value greater than or e

Strany 145

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 221The time that is required by each sensor to make a measurement must

Strany 146 - PRIVILEGES

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 15 01/07/11,14:13:55,23.7,13.8, 01/07/11,14:14:55,23.7,13.8, 01/07/11,

Strany 147

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 222  If you plan to read each sensor N times, then the total time re

Strany 148

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 223If Ttotal is less than the Sample Duration Time, the ZENO®-3200 wil

Strany 149 - ENTIRE CONFIGURATION

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 224If User Interface accessibility is periodically disrupted by your c

Strany 150

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 225 SENSOR MENU (Cn/m) Change Item n To Value m (Jn) Jump

Strany 151

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 226Examples of using Line Item #25 include:  Only collecting data fr

Strany 152

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 227The ZENO®-3200 will return the floating-point values 15.2, 55.999,

Strany 153 - VERSIONS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 228Changing one of these parameters will change the total amount of me

Strany 154

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 229The contents of a Command Line are changed using menu option Cn/m{E

Strany 155 - SPECIFICS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 230 Hand-edit the downloaded configuration file using a standard tex

Strany 156 - 10.3. DEFINING THE SENSORS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 231Command Category Brief Description FLOAT n LONG n STRING n (l1[,

Strany 157 - Refer to Section 12.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 16If you are curious about the data logging capacity of your ZENO®-320

Strany 158 - 10.3.1. Analog Sensors

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 232Each string value will be referred to as S1, S2, etc. within the re

Strany 159

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 233 The serial communications port specified in the Sensor Record is a

Strany 160

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 234The checksum Special Value, sCS, may not be referenced before the S

Strany 161 - 10.3.2. Digital Sensors

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 235Three types of information can be used in the Format Specifier: Typ

Strany 162

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 236Data Field Description Data Value Field %% Represents character %

Strany 163

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 237Determine exactly what is contained in a sensor's data message

Strany 164

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 238 Troubleshooting the RECEIVE Command Format Specifier Once commun

Strany 165

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 239communications port that supports one or more serial sensors can ca

Strany 166

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 240In operation and properly configured, the primary ZENO®-3200 will r

Strany 167

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 24113. ELECTRICAL CONSIDERATIONS Coastal Environmental Systems ZENO®-

Strany 168

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 17 DATA RETRIEVAL MENU (A) Show Records AFTER Specified Time

Strany 169

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 242 DC offset voltages arise due to large currents flowing through t

Strany 170

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 243 Sensor ground (marked SGND): this ground should be used only for

Strany 171

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 244If the source “low” output is connected to ground (either directly

Strany 172

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 24513.4. THE ZENO®-3200 CPU BOARD The following is a diagram of the Z

Strany 173 - Refer to Section 6.12

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 246Each COM port provides unique communications link access, which is

Strany 174

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 247Pin Rev. A Function Rev. D Function 1 DCD (Data Carrier Detect)

Strany 175 - Refer to Section 10.3.5

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 248The 25 pins have the following functions: Revision A Revision D

Strany 176

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 24913.5.3. Revision A and Revision D, ZENO®-3200 Communication Wiring

Strany 177

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 250Compass Port (J3 on CPU Board) Pin # Description 1 12 V Switched

Strany 178

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 251Connecting To COM3 Where to Connect COM3 Port Type Lines Required

Strany 179

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 18 > f SYSTEM FUNCTIONS MENU (Cn/m) Change Item n To Value m

Strany 181

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page A-1A. CONSTANTS, CONVERSIONS & ASCII TABLE Coastal Environmental

Strany 182

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page A-2Physical Properties of Water Property Value Density 1000 kg/m3 Spe

Strany 183

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page A-3 1 cubic yard = 27 cubic feet = 46,656 cubic inches LIQUID VOLUME

Strany 184 - Page 176

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page A-4 1 acre = 4,046.85 sq. meters  1 square mile = 2.59 sq. km PHYS

Strany 185

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page A-5 DEC is the decimal (base 10) value  CHR is the actual characte

Strany 186

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page A-6

Strany 187

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page B-1B. ZENO®-3200 MENU LISTING Coastal Environmental Systems ZENO®-32

Strany 188 - 10.5. DEFINING CONSTANTS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page B-2USER MENU C COMMUNICATIONS MENU 1 Baud rate for COM 1 2 Baud rat

Strany 189 - Refer to Section 4

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page B-33 Self-Timed Transmission Interval format is 'dd:hh:mm:ss&apo

Strany 190

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 19 > c4/2 SYSTEM FUNCTIONS MENU (Cn/m) Change Item n To Value m

Strany 191

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page B-43 Alternative Source Address 4-11 Remote ZENO Address #1 - #8 R

Strany 192

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page B-5B Display BIT Status Section 7.6 Ex Display Sensor x Error Codes

Strany 193

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page B-612: COM1, COM2, COM3 13,17,18: COM2, COM3 14: CH10 through CH16 (u

Strany 194 - Page 186

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page B-77 - Differential 8 - Free-Running Average 9 - Collection 10 -Trend

Strany 195

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page B-85 - Arithmetic Processes Category 1 - U-V Vectors To Magnitude-Dire

Strany 196

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page B-94 Input Record Depends on number & type of Sensor & Process

Strany 197

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page B-10

Strany 198

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-1 C. SENSOR CONFIGURATIONS Coastal Environmental Systems ZENO®-3200 Use

Strany 199 - Refer to Section 10.4.4

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-2 ITEM DATA COMMAND ENTERED Item 1: Field Type code = 9 : Transmit

Strany 200

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-3 ITEM DATA COMMAND ENTERED Item 1: Sensor Type code = 2 (18-bit Sin

Strany 201

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 203.1.3. Understanding & Changing the Sample Interval and Power U

Strany 202

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-4 * When changing resistor values to measure different voltage ranges

Strany 203 - Refer to Section 4.4.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-5 ITEM DATA COMMAND ENTERED Item 1: Field Type code = 9 : Transmit

Strany 204

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-6 PROCESSING MENU ITEM DATA COMMAND ENTERED Item 1: Process Category

Strany 205

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-7 2. 2 - wire sensor Coastal Environmental Systems (CES) suppli

Strany 206

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-8 PROCESS MENU ITEM DATA COMMAND ENTERED Item 1: Process Category code

Strany 207 - Refer to Section 4.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-9 6. HYGROMETRICS 10205H/HT RELATIVE HUMIDITY SENSOR MENU ITEM

Strany 208 - Refer to Section 6.1

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-10 ITEM DATA COMMAND ENTERED Item 1: Field Type code 9 : Transmit

Strany 209

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-11 ITEM DATA COMMAND ENTERED Item 1: Sensor Type code = 3 (18-bit Di

Strany 210

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-12 Settings for Temperature ITEM DATA COMMAND ENTERED Item 1: Field T

Strany 211

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-13 8. SDI-12 SENSOR298 SENSOR MENU Settings for SDI-12 SENSOR on COM2

Strany 212

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 21 Sample Interval |---------------------------------------| 60 sec

Strany 213 - 11. ALARM MESSAGES

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-14 Notes on Connection The SDI-12 data line uses negative logic 0 to 5V

Strany 214

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-15 4.99 k Settings for Temperature ITEM DATA COMMAND ENTERED Item 1:

Strany 215

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-16 10. R.M. YOUNG 05103 WIND MONITOR SENSOR MENU Settings for Wind Dire

Strany 216 - Refer to Section 6.8

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-17 Settings for Wind Direction/Wind Speed ITEM DATA COMMAND ENTERED It

Strany 217 - ALARM MESSAGE

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-18 * Refer to the sensor's manual for correct signal names. 11. EL

Strany 218 - Refer to Section 11.3.1

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-19 ITEM DATA COMMAND ENTERED Item 1: Sensor Type code = 16 (General

Strany 219

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-20 COMMANDS TO ENTER I1 C1/STRING 4 ( 90, 1, 2, 4 ) I2 C2/FLOAT 9 I3 C3/

Strany 220

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-21 ITEM DATA COMMAND ENTERED Item 1: Process Category Code = 1 : Gen

Strany 221

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-22 Settings for First Cloud Level ITEM DATA COMMAND ENTERED Item 1: F

Strany 222 - 3200 CONFIGURATION

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-23 12. VAISALA300 425AH OR 425AHW ANEMOMETER The Vaisala 425AH anemomet

Strany 223 - -3200 Internal Clock

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page i Table of Contents TABLE OF CONTENTS ...

Strany 224 - and Multitasking

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 22Hour of the Day 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1

Strany 225 - Refer to Section 10.3.7

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-24 ITEM DATA COMMAND ENTERED Item 1: Sensor Type code = 16 (General

Strany 226

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-25 COMMANDS TO ENTER I1 C1/STRING 1 ( 50 ) I2 C2/SEND "\B " I3

Strany 227 - Records

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-26 ITEM DATA COMMAND ENTERED Item 1: Process Category Code = 5 : Ari

Strany 228

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page C-27 Settings to Collect Data From Vaisala 425AH Sensor on COM2, Average

Strany 230 - TNTNTNTNTNT

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-1 D. ZENO®-3200 PROCESS LIBRARY Coastal Environmental Systems ZENO®-320

Strany 231 - Refer to Section 10.3.8

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-2 The Averaging Process calculates the average of the data referenced in

Strany 232 - 12.2.2. The Sensor Menu

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-3 The Running Average will not contain an average specified by the Runn

Strany 233 - Refer to Section 12.2.3

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-4 Since Bad Sensor Values (BSVs) are NOT processed313, they are NOT ent

Strany 234 - Refer to Section 12.2.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-5 Each block contains the sum total (Tblock) of the values that were rea

Strany 235

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 23 Going to the Data Retrieval Menu (type U{ENTER} D{ENTER}), and lo

Strany 236

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-6 1.6. Rate of Change Process Inputs: 4 Any sensor or process output

Strany 237

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-7 1.8. Free-Running Average Process Inputs: 4 Any sensor or process o

Strany 238 - Refer to Section 9.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-8 1.10. Trend Data Process Inputs: 4 Any sensor, process or constant

Strany 239

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-9 Assumptions: Null inputs are not processed The Multiple Input Minimum

Strany 240

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-10 Assumptions: None When the control data is 0, the Validated Data outp

Strany 241

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-11 xyusxvsyiiiiiiiiiisin ;cos ;;; giving xi and yi, the unit vecto

Strany 242

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-12 2211211NNiiNiiN, with i defined such that each 

Strany 243 - ", % and \

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-13 15 Wind Direction during Running Maximum Wind Gust Speed 16 Run

Strany 244

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-14 Assumptions: This process assumes that the wind direction will not c

Strany 245

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-15 When the vehicle is stationary, the True Wind Vector Average Process

Strany 246

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 2412. How much and how often do I want the ZENO®-3200 to perform the c

Strany 247 - (MULTIPROCESSING)

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-16 2.6. Rainfall Process Inputs: 4 Rain Data 5 Rain accumulation in

Strany 248

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-17  Divide the number of required running intervals by 7 and round it

Strany 249 - CONSIDERATIONS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-18 The algorithm is that in “Principles of Meteorological Analysis”, by

Strany 250 - Converter

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-19 Calculating the wet-bulb temperature (TW) begins with the following e

Strany 251

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-20 13 Longitude of the standard time zone meridian 14 Radiation senso

Strany 252 - Chassis

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-21 a long-wave emissivity of the atmospheres long-wave surface emis

Strany 253 - 13.5. SERIAL PORT WIRING

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-22 aTe108 1100Pa2016.exp , (5) where the air tempe

Strany 254

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-23 The canopy resistance is set to 70 sm-1. During the night, the canopy

Strany 255

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-24     TTaTTTa**;*Jkg;Jkg K ;46143112.501 102.37 10

Strany 256

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-25 If a NULL compass is defined, the value of Add Compass To Vane has no

Strany 257

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 25ZENO®-3200 Configuration Recipe Card 1. Configure the sensors. 2. Co

Strany 258

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-26 Variable Definition AS Altimeter Setting PV Lowest Valid Pressure T

Strany 259

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-27 The following variables are used by this process: Variable Descripti

Strany 260

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-28 5 Peak Wind Speed Alert Flag 6 Data Invalid Flag E1 Proces

Strany 261 - CONVERSIONS & ASCII

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-29 1. Two running averages are calculated--all the winds to the "l

Strany 262 - 2. CONVERSION CONSTANTS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-30 Unless otherwise stated, digital outputs are set high or low only whe

Strany 263

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-31 3.2. Data Range Process Inputs: 4 Any sensor or process output 5

Strany 264 - 3. ASCII CODES

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-32 Assumptions: If the Alarm Reset value is less than the Alarm Set-poi

Strany 265

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-33 This process is used to acknowledge (set to low) an alarm set by eith

Strany 266 - Page A-6

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-34 Value Referenced in Line Item #4 of Two-Range Alarm Value Referenced

Strany 267 - -3200 MENU

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-35 The Missing Sensor Data Process allows the setting of an alarm condit

Strany 268 - Page B-2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 26 Enter Administrator Password: **** Waiting for all data acquisitio

Strany 269 - Page B-3

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-36 defined, the digital outputs and switched voltage are set high and an

Strany 270 - Page B-4

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-37 Assumptions: May be used for a weighed bucket rain sensor The Increm

Strany 271 - Page B-5

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-38 The Error Checking Alarm Process is an excellent tool for discovering

Strany 272 - Page B-6

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-39 The One-shot Daily Timed Event Process is similar to the Timed Event

Strany 273 - Page B-7

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-40 E1 Process Error Code Assumptions: Sensor data is scaled to show

Strany 274 - Page B-8

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-41 Assumptions: This process is intended for the Paroscientific baromet

Strany 275 - Page B-9

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-42 Thermocouple Type Lowest Valid Voltage (µV) First Midrange Voltage (µ

Strany 276 - Page B-10

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-43 All immediate temperatures calculated by this process are averaged to

Strany 277 - CONFIGURATIONS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-44 6 Thermopile output (any sensor, process or constant output) 7

Strany 278

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-45 E1 Process Error Code Assumptions: None This process takes the squ

Strany 279

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 27A Process Record can refer to any Sensor Record or any preceding Pro

Strany 280 - 3. BAROMETRIC PRESSURE

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-46 5.7. Divide Two Data Values Process Inputs: 4 Dividend (D) 5 Divisor

Strany 281 - 4. 20MA CURRENT LOOP

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-47 5.13. Conditional Select Process Inputs: 4 Control Data C (D) 5

Strany 282

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page D-48 6. OUTPUT AND CONTROL PROCESSES CATEGORY 6.1. DAC Analog Output Pro

Strany 283

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page E-1E. CONFIGURATION FILE CONTENTS Coastal Environmental Systems ZENO®-320

Strany 284

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page E-22. CONTENTS OF RUN-TIME PARAMETER LINES For interested users, the foll

Strany 285

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page E-3- Output message #2 COM port  The line beginning PARAM4 contains the

Strany 286 -  PLATINUM RTD

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page E-4- ARGOS checksum flag - Response delay time - Daylight savings time

Strany 287

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page E-5- BIT name #10 - BIT name #11 - BIT name #12 - BIT name #13 - BIT

Strany 289 - 8. SDI-12 SENSOR

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-1F. LIBRARY OF CCSAIL COMMANDS Coastal Environmental Systems ZENO®-3200

Strany 290 - DEFAULT

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 28 ZENO PROGRAM MENU (S) Sensor Menu (M) Memor

Strany 291

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-2 Requires Requires CCSAIL Command Active CTS Halted Data Col. A

Strany 292

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-3This command is returned from either HOST or the REMOTE to indicate a n

Strany 293

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-4Global or addressed time set command. No message is returned from the

Strany 294 - 11. ELLIASON CEILOMETER

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-5To ID 0134 from 0001, send all data collected since last D@nn or DX@nn

Strany 295

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-6DLnn, DXLnn, Request the latest, most recent nn data sets stored in dat

Strany 296

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-7Request nn unmarked data sets. This command behaves similarly to option

Strany 297

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-86. DIGITAL OUTPUT CONTROL COMMANDS SDOxyy, This command instructs the

Strany 298

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-9This CCSAIL command instructs the ZENO®-3200 to immediately reboot. Th

Strany 299 - 425AH OR 425AHW ANEMOMETER

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-10ZENO®-3200 number 134 to change the sample period to 30 seconds would

Strany 300

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-11If the user attempts to change any of these parameters while the ZENO®

Strany 301

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 29 > H1 * Select Sensor Type Code, valid codes are - 0 (No

Strany 302

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-12ZENOSOFT® will respond with a CCSAIL ERROR 6 if ASCII parameter nnn is

Strany 303

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-13This CCSAIL command will set the floating-point value of all constants

Strany 304

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-14 GETREPEATnnn, Retrieve the value of the nnnth eight remote addresses

Strany 305 - -3200 PROCESS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-15#12340001ENDSAMPLE60^C The ZENO®-3200 would respond with: #00011234OK,

Strany 306

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-16ERROR14,29^C 10.5. Create Default Configuration DEFAULTCONFIG This

Strany 307 - Refer to Section 3.1.3

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-17If script number nnn does not exist, ZENOSOFT® will respond with a CCS

Strany 308 - 1.4. Block Average Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-18SETGSInnn,mmm,abcde, Change line number mmm in script number nnn to co

Strany 309 - 1.5. Accumulation Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-19#12670001STARTSAMPLE49^C #00011267OK,99^C GETGSInnn, This command ins

Strany 310 - 1.7. Differential Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-20placed after record number mmm. If n is B, the new record is placed b

Strany 311 - 1.9. Collection Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-21#00015310ERROR61,56^C #53100001SETDATA14,9 1 "AWSPD" P1.11 1

Strany 312 - 1.10. Trend Data Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 30As you can see, the value for Line Item #1 (the Sensor Type Code) ha

Strany 313

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page F-22When the sensor, process or data output records are deleted, any subse

Strany 314 - Refer to Section 5.7

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-1G. INDEX Coastal Environmental Systems ZENO®-3200 User Manual { {{{{{

Strany 315

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-2Alarm Process, 183, 209, 210, D-31, D-32, D-33, D-34, D-37, D-38, D-39

Strany 316

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-3BIT, 18, 19, 60, 62, 70, 73, 119, 120, 134, 136, 138, 139, 166, 200, 20

Strany 317

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-4COM3 Baud Rate, 78 COM3 Port Type, 78 comma delimited, 14, 17, 18, 60,

Strany 318

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-5Data Rounding Process, D-48 Data Storage Class Code, 48, 49, 50, 51, 18

Strany 319 - Refer to Section 5.8

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-6FAA SAWS Wind Gust Process, D-26, D-28 FAA Wind Data Transmit Only, 190

Strany 320 - 2.6. Rainfall Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-7Hygrometrics 10205H/HT Relative Humidity, C-9 I IDC MOM14400, 85 Immedi

Strany 321 - 2.7. Dewpoint Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-8modify a configuration, 149 MOnitoring Raw or Scaled Sensor Data, 134 m

Strany 322

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-9Permittivity Constant, A-1 Pi, A-1 PIR Temperature Correction, 179, D-4

Strany 323 - 0091379024.066082.26

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 31> C2/IntTemp SENSOR MENU (Cn/m) Change Item n To Value m

Strany 324 - 089 1 1

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-10Real Time Output Format, 18, 19, 60, 62, 66, 70, 73, 197, 198, 199, 20

Strany 325 -     

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-11Sensor Baud Rate, 163, 228, B-6, C-19, C-24 Sensor Bits Per Character,

Strany 326

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-12Speed of Light, A-1 Speed Over Ground, 159 standard deviation, 42, 136

Strany 327

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-13TXA, 79, 97, 251 U UART, 76 u-component, D-13 UDP, 92, 93 unauthorized

Strany 328 -     

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page G-14Wind Vector Average, 74, 179, B-7, C-17, C-26, D-10, D-12, D-13, D-14,

Strany 329

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page ii 4.4.2. Real Time Data Output Message Format...

Strany 330

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 32No exterior physical connections are required to measure the Interna

Strany 331

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 33 > C3/INT SENSOR MENU (Cn/m) Change Item n To Value m

Strany 332

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 34> C12/2 SENSOR MENU (Cn/m) Change Item n To Value m

Strany 333 - 3. ALARM PROCESSES CATEGORY

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 35 > A SENSOR MENU (Cn/m) Change Item n To Value m (Jn

Strany 334

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 36 > C1/1 C2/Battery C3/BATT C12/2 SENSOR MENU (Cn/m) Change Item

Strany 335 - 3.3. Alarm Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 373.2.4. Learning How To Configure A Process From the Zeno Program Me

Strany 336 - 3.5. Alarm Reset Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 38To aid in identifying the type of process desired, each numerical Pr

Strany 337

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 39Since the Process Category in Line Item #1 is already set to 1, it d

Strany 338

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 40 > C3/AvgTemp PROCESS MENU (Cn/m) Change Item n To Value m

Strany 339 - 3.9. Multiple Alarm Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 41 > C4/S1 PROCESS MENU (Cn/m) Change Item n To Value m

Strany 340 - Refer to Section 11.3.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page iii 6.8.1. Applying To Use ARGOS ...

Strany 341 - Refer to Section 10.4.5

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 42Error Code.40 You can view the available outputs of any Process Rec

Strany 342 - 3.13. Timed Event Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 43Since you have reached another milestone during the configuration pr

Strany 343 - 4.1. NTC Thermistor Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 44 > H1 * Select Field Type Code, valid codes are - 0 (NUL

Strany 344 - ABRC R ln (ln )

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 45 > C1/6 DATA OUTPUT MENU (Cn/m) Change Item n To Value m

Strany 345 - 4.3. Thermocouple Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 46 > C3/<D><A> DATA OUTPUT MENU (Cn/m) Change Item n T

Strany 346

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 47Type the command string A C1/9{ENTER} in the Data Output Menu to cre

Strany 347 - 4.5. UV Biometer Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 48Line item #7 specifies the Data Storage Class Code. If we type H7{E

Strany 348 - TTKTEPIR 

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 49You now need to set up the last Data Output Record to log and transm

Strany 349

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 50Your screen should look the following: > C3/AvgBatt C4/P2.1 DAT

Strany 350

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 514. RETRIEVING LOGGED DATA Coastal Environmental Systems ZENO®-32

Strany 351 - 5.16. Data Rounding Process

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page iv 10.4.2. User-Defined Process Name...

Strany 352

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 52If you need to adjust the internal ZENO®-3200 clock backward, to avo

Strany 353 - CONTENTS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 53The content of each Data Record is defined in the Data Output Menu.5

Strany 354 - Refer to Section 9.4

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 54You would type the command L5{ENTER} in the Data Retrieval Menu and

Strany 355

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 55NOTE: The M command will work regardless of when the last @n comman

Strany 356 - - Zero-offset check period

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 56 DD is the day (1 to 31)  HH is the hour of day (00 to 23)  MM

Strany 357

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 57The X-modem protocol should be used on any communications interface

Strany 358

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 58In this particular case, the total amount of memory for data logging

Strany 359 - COMMANDS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 59 SYSTEM FUNCTIONS MENU (Cn/m) Change Item n To Value m

Strany 360 - 2. RESPONSES

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 604.4.2. Real Time Data Output Message Format Real time output messag

Strany 361 - 3. TIME COMMANDS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 61-1,000,000 is referred to as the Bad Sensor Value. If you do not wan

Strany 362 - 4. DATA RETRIEVAL COMMANDS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page v 13. ELECTRICAL CONSIDERATIONS ...

Strany 363 - Refer to Section 4.1.5

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 62Coastal Environmental Systems’ PC application, Intercept™ uses the C

Strany 364 - Refer to Section 4.1.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 63The Destination and Source Addresses must each be four characters in

Strany 365 - 5. USER INTERFACE ACCESS

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 64The ZENO®-3200 only responds to a validated CCSAIL message. The res

Strany 366

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 65Destination Address = 1025 Source Address = 0100 Command =

Strany 367 - Refer to Section 6.9.2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 66Coastal Environmental Systems' PC application Intercept™ expect

Strany 368

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 67Difference Internal connection. Connected directly to the CPU via 32

Strany 369

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 684.7.2. Retrieving Flash Logging Memory Status If you want to retrie

Strany 370 - Refer to Section 10.5

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 695. INTERNAL ZENO®-3200 SETTINGS Coastal Environmental Systems ZENO

Strany 371 - Refer to Section 6.10

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 705.1. ZENO®-3200 SYSTEM DATE AND TIME Option S in the System Functio

Strany 372

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 71Temperature Sensor is also used to know when the internal temperatur

Strany 373

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page vi Acknowledgements The author, Michael J. Hart, personally thanks each of

Strany 374

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 72The Primary Unit ID is the unique identification number that can be

Strany 375

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 73The Secondary Unit ID is a unique identification number that can be

Strany 376

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 746. COMMUNICATION INTERFACES Coastal Environmental Systems ZENO®-3

Strany 377 - Refer to Section 10

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 75After connecting and powering up the ZENO®-3200 as described in Sect

Strany 378

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 76The Communications Menu lets you change the communications settings

Strany 379

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 77The following table summarizes the available settings for each commu

Strany 380

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 78In half-duplex mode, when data are being dumped from the Data Output

Strany 381 - G. INDEX

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 796.2. DIRECT TERMINAL ACCESS The following is the schematic of the Z

Strany 382

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 80The ZENO®-3200 does not actively assert/de-assert RTS. Instead, the

Strany 383

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 81 USER MENU (C) Communications Menu (T) Test Menu (F)

Strany 384 - , 74, E-2

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 11. INTRODUCTION Coastal Environmental Systems ZENO®-3200 User Manua

Strany 385

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 82 MODEM MENU (Cn/m) Change Item n To Value m (Q) Quit (E)

Strany 386

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 83 A modem connection to COM3 has been specified in the Modem Menu but

Strany 387

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 84the correct cable (typically the manufacturer’s modem cable). If yo

Strany 388

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 85*WARNING: If you wish the ZENO®-3200 to dial out, DIP switch #3 must

Strany 389 - Rain Data, D-16

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 86We also recommend that you force the baud rate between the two modem

Strany 390 - , 20, 21, 22, 51, 52, 220, B

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 87Echo Off Normally, a modem echoes all commands it receives. for exa

Strany 391

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 88ZENO COM3 DE-9F MODEM DE-9F shield DCD 1 1 DCD RXD 2 2 RXD

Strany 392

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 89connect and communicate at 4800 BPS. This can be accomplished in tw

Strany 393

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 90Cellular Modem Type Manufacturer AMPS StarComm Cellular Modem 1442E

Strany 394

ZENO®-3200 USER MANUAL Coastal Environmental Systems (206) 682-6048 Page 912. Device Type: Your cellular provider may ask you to identify the

Komentáře k této Příručce

Žádné komentáře

Bissell Steam Shot 16Q1E SERIES Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Dampfreiniger Bissell Steam Shot 16Q1E SERIES.
Wir stellen 1 PDF-Handbücher Bissell Steam Shot 16Q1E SERIES zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Betriebsanweisung






Weitere Produkte und Handbücher für Dampfreiniger Bissell

Modelle Dokumententyp
Steam Mop BS-1867F Betriebsanweisung    Bissell Steam Mop BS-1867F User`s guide, 20 Seiten
9595 Betriebsanweisung    Bissell 9595 User`s guide, 16 Seiten
23B6-F SERIES Betriebsanweisung    Bissell 23B6-F SERIES User`s guide, 12 Seiten
Steam Mop Betriebsanweisung    Bissell Steam Mop User`s guide [en] , 12 Seiten
23V8-F SERIES Bedienungsanleitung   USER`S GUIDE, 12 Seiten
PROHEAT II Betriebsanweisung   Bissell PROHEAT II User`s guide, 24 Seiten
Steam Mop Deluxe Bedienungsanleitung   steam mop - Alpaytac [en] , 1 Seiten
1957-F SERIES Betriebsanweisung    Bissell 1957-F SERIES User`s guide [en] , 12 Seiten
Steam Mop 1867 SERIES Betriebsanweisung   Bissell Steam Mop 1867 SERIES User`s guide [en] [ru] , 12 Seiten
4207 Betriebsanweisung   Bissell 4207 User`s guide, 12 Seiten
Pawsitively Clean yowza 94U5 SERIES Betriebsanweisung   Bissell Pawsitively Clean yowza 94U5 SERIES User`s guide [en] , 16 Seiten
Proheat 25A3 SERIES Betriebsanweisung   Bissell Proheat 25A3 SERIES User`s guide, 20 Seiten
40M1 series Betriebsanweisung   Bissell 40M1 series User`s guide, 20 Seiten
1816 Bedienungsanleitung Dashboard, 5 Seiten
STEAM SHOT 39N7 Betriebsanweisung   Steam Shot™ [en] , 12 Seiten
Lift-Off Steam Mop Hard Surface Cleaner Betriebsanweisung   Bissell Lift-Off Steam Mop Hard Surface Cleaner User`s guide, 12 Seiten
3 3 N 7 Betriebsanweisung   Bissell 3 3 N 7 User`s guide, 20 Seiten
Lift-Of 23B6-J SERIES Bedienungsanleitung    на русском языке, 24 Seiten
1548 Bedienungshandbuch   Bissell 1548 Owner's manual, 20 Seiten
Swiffer BISSELL STEAMBOOST Steam Mop 6639 Bedienungshandbuch     Bissell Swiffer BISSELL STEAMBOOST Steam Mop 6639 Owner's Manual, 2 Seiten