Campbell CSAT3 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro ne Campbell CSAT3. 3-D sonic anemometer Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 9
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 1 -
3-D sonic anemometer
Standard Operating Procedure (SOP)
for the Baltimore PM Supersite
January, 2001
Markus Pahlow
Marc B. Parlange
Johns Hopkins University
Department of Geography and Environmental Engineering
313 Ames Hall
3400 North Charles St
Baltimore, MD 21218
Zobrazit stránku 0
1 2 3 4 5 6 7 8 9

Shrnutí obsahu

Strany 1 - 3-D sonic anemometer

D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 1 - 3-D sonic anemometer Standard Operating Procedure (SOP) for the Baltimore PM Supersite Janu

Strany 2

D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 2 - Measurement of wind speed and air temperature and computation of sensible heat and momentum flu

Strany 3 - 3. Data Quality Objectives

D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 3 - The sonic transducers are sealed and will not be damaged should they become wet. The wind measu

Strany 4 - 5. Wiring

D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 4 - 4. Installation 4.1 Orientation The three wind components are defined by a right handed ortho

Strany 5 - 6. CSAT3 Output

D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 5 - Battery Terminal Description Color Positive 12 VDC Red Negative Ground Black Table 1. CSAT3 P

Strany 6 - 9. Data Transfer

D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 6 - CSAT3 will send wind speed and the sonic virtual temperature via the SDM bus to the datalogger.

Strany 7 - 11. Maintenance

D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 7 - 10. Daily Checks Check if current time is displayed on CR23X. This means that data logger has

Strany 8 - Appendix 1

D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 8 - Appendix 1. Sample Program for SDM-CSAT3 (P107) used with CR23X ;{CR23X};*Table 1 Program01: 0.

Strany 9

D:\Shared on Tuch\SOP\JHU_SOPsonic_v03.doc - 9 - 12: If Flag/Port (P91)1: 10 Do if Output Flag is High (Flag 0)2: 10 Set Output Flag High (Flag