Interfacing the MICROCOM DESIGN GTX Modulator to the Campbell Scientific CR1000 Data Logger PRELIMINARY
GTX to
CR1000
Connections:
Figure 1 is a block diagram which shows the connections used for this Application note. Our test
PC uses three separate serial ports which are used to interface and program the GTX and the
CR1000 data logger.
Figure 1 GTX to CR1000 EXAMPLE SERIAL CONNECTIONS
Satellite Data Transmitter
GTX - 1.0
OUT
RF
RF OUT
1
2
12.5Vdc
-+
INPUT
POWER
12.5Vdc
8
TX
TX
FS TRIPPED
10
FS
11
9
FS RESET
DATA
GPS
SDI-12
PORT
SERIAL
GPS ANT
CAN/TB
I/0
SDI 12
RESET
FAILSAFE
DATA
GPS
RS-232
7
6
TB
CAN
I/O
4
ANT
GPS
3
5
Figure 2 Microcom GTX Satellite Transmitter
1. Main Power Input Connector - +12.5 VDC
2. RF Output Connector
3. CAN (future) and Tipping Bucket Connector
4. GPS Antenna Connector
5. RS-232 Serial Port Connector
6. SDI-12 Interface Connector
7. Failsafe Reset Push-Button
8. LED4: Data in Transmit Buffer LED (Green)
9. LED3: GPS Receive Active LED (Green)
10. LED2: RF Transmit Active LED (Green)
11. LED1: Failsafe Tripped LED (Red)
© 2005 Microcom Design Inc. All rights reserved voice: 401.771.1070 Fax:410.771.0018