User Manual 1 Mems Tiltmeter (IPI Sensor Based) User Manual Man193 2.0.2 07/08/2014 Final Chris Rasmussen Phil Day Manual No. R
User Manual 10 Sample Installation Record Sheet Section 6 : MEMS Tiltmeter Installation Sheet Date Installer Site Location Sensor Number Se
MEMS Tiltmeter (IPI Sensor Based) User Manual 11 Sample Calibration Sheet Section 7 : Bell Lane, Uckfield, East Sussex t: +44
User Manual 2 Contents Introduction ...
User Manual 3 Introduction Section 1 : The Soil Instruments Mems Tiltmeter is based on the Soil Instruments In Place Inclinometer (IPI) sensor.
User Manual 4 Installation Section 2 : The following tools are required for installation; 3mm & 5mm Allen keys A drill and bit suitable
User Manual 5 Wiring Section 3 : The Soil Instruments tiltmeter sensor can be read by most commercially available dataloggers. Soil Ins
User Manual 6 Taking Readings/Logger Programming Section 4 : The Soil Instruments tiltmeter sensors are designed to be read by Campbe
User Manual 7 1: 78 Pulse Port 8 ; Activate SW12Volt 4: Do (P86) 1: 47 Set Port 7 High ; Let the sensors warm up for at least 3 seconds 5: Exc
User Manual 8 If in any doubt we recommend contacting Soil Instruments for advice. The performance of the sensors as calibrated is not guarante
User Manual 9 Data Reduction Section 5 : The Soil Instruments tiltmeter sensor is calibrated over ±5 or ±10 arc degrees (approx. ±87 or ±175mm/met