INSTRUCTION MANUAL
Model HFP01SC Self-Calibrating
Soil Heat Flux Plate
Revision: 3/14
Copyright © 2002- 2014
Campbell Scientific, Inc.
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL Model HFP01SC Self-Calibrating Soil Heat Flux Plate Revision: 3/14 Copyright © 2002- 2014 Campbell Scie

Strany 2

Model HFP01SC Self-Calibrating Soil Heat Flux Plate The location of the heat flux plates and thermocouples should represent the area of study. If the

Strany 3 - Warranty

Model HFP01SC Self-Calibrating Soil Heat Flux Plate TABLE 6-1. Datalogger Connections for a Single-Ended Measurement Description Color CR10X CR

Strany 4 - Assistance

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 6.2 Wiring Connections to Campbell Scientific dataloggers are given in FIGURE 6-1, TABLE 6-1, and

Strany 5 - Table of Contents

Model HFP01SC Self-Calibrating Soil Heat Flux Plate Heater Resistor Signal #1 Yellow 13H Heater Resistor Signal Reference #1 Purple Shield #1 Cle

Strany 6

Model HFP01SC Self-Calibrating Soil Heat Flux Plate BeginProg 'HFP01SC factory calibration in W/(m^2 mV) = 1000/sensitivity. shf_cal(1) = HFP

Strany 7 - Model HFP01SC

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 6.3.2 Example 2. Sample CR10(X) Program Using a Single-Ended Measurement Instruction TABLE 6-4 p

Strany 8 - 5. Specifications

Model HFP01SC Self-Calibrating Soil Heat Flux Plate ;Factory calibration in W/(m^2 mV) = 1000/sensitivity. ; 4: Z=F (P30) 1: 1 F ; <- Ente

Strany 9 - 6. Installation

Model HFP01SC Self-Calibrating Soil Heat Flux Plate *Table 2 Program 02: 0 Execution Interval (seconds) *Table 3 Subroutines ;Calibration rout

Strany 10

Model HFP01SC Self-Calibrating Soil Heat Flux Plate ;Stop filtering data. ; 12: If time is (P92) 1: 39 Minutes (Seconds --) into a 2: 180

Strany 11

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 6.3.3 Example 3. Sample CR23X Program Using a Differential Measurement Instruction TABLE 6-5 pro

Strany 13

Model HFP01SC Self-Calibrating Soil Heat Flux Plate ;Factory calibration in W/(m^2 mV) = 1000/sensitivity. ; 4: Z=F (P30) 1: 1 F ; <- Ente

Strany 14

Model HFP01SC Self-Calibrating Soil Heat Flux Plate *Table 2 Program 02: 0 Execution Interval (seconds) *Table 3 Subroutines ;Calibration rout

Strany 15 - Measurement Instruction

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 13: Do (P86) 1: 218 Set Flag 18 Low ;Compute in-situ calibration. ; 14: Z=X (P31) 1:

Strany 16

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 6.3.4 Example 4. Sample CR10X Program Using External Power and Relay TABLE 6-6 provides the sens

Strany 17

Model HFP01SC Self-Calibrating Soil Heat Flux Plate ;{CR10X} ; *Table 1 Program 01: 1 Execution Interval (seconds) ;Measure HFP01SC on smalles

Strany 18

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 11: Beginning of Loop (P87) 1: 0 Delay 2: 6 Loop Count ;Use data from the larger mea

Strany 19

Model HFP01SC Self-Calibrating Soil Heat Flux Plate *Table 3 Subroutines ;Calibration routine. ; 1: Beginning of Subroutine (P85) 1: 8 Subrout

Strany 20

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 15: End (P95) ;Compute in-situ calibration. ; 16: If time is (P92) 1: 39 Minutes (Second

Strany 21

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 5 shf_5 0 0 0 6 shf_6 0 0 0 7 shf_mV_1 1 5 2 8 shf_mV_2 1 0 1 9 shf_mV_3 1 0 1 10 shf_m

Strany 22

Model HFP01SC Self-Calibrating Soil Heat Flux Plate θρρθmwbv= (2) where CS is the heat capacity of moist soil, ρb is the bulk density, ρw is the dens

Strany 23

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Strany 24

Model HFP01SC Self-Calibrating Soil Heat Flux Plate TABLE 6-8. Hukseflux and Campbell Scientific Variable Names Description Hukseflux Campbell Sci

Strany 26

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strany 27

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strany 28 - = + = +ρ θ ρ θ ρ

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Strany 29

Table of Contents ii

Strany 30 - 8. References

Model HFP01SC Self-Calibrating Soil Heat Flux Plate 1. Introduction The HFP01SC Self-Calibrating Heat Flux Sensor measures soil heat flux, typicall

Strany 31

Model HFP01SC Self-Calibrating Soil Heat Flux Plate In order to measure soil heat flux at the surface, several HFP01SCs are used to measure the soil h

Strany 32

Model HFP01SC Self-Calibrating Soil Heat Flux Plate Sensor: Thermopile and film heater Heater Voltage Input: 9 to 15 Vdc Heater Voltage Output: 0 t