Relay
Control
Microcontroller
12V
GROUND
RESET
CLOCK
COM HI
COM LO
CR800/CR1000
Sensor #1
Sensor #32
12V
GROUND
RESET
CLOCK
Multiplexer/Terminal Board
AG
Sensor
Shield
Sensor
Shield
1H
1L
S1
32H
32L
S16
Figure 2 - 32 Channel Switching Block Diagram
The 32 channel 2 wire switching configuration is typically used to multiplex 2 wire
sensors such as a vibrating wire pressure transducers, thermistors or thermocouples.
The multiplexer is powered by a nominal 12 VDC supply. Two control lines (RESET
and CLOCK) determine how channel selection is accomplished. Two schemes are
supported - one when connected to the GK-403 Vibrating Wire Readout Box and the
other when connected to MICRO-800 or MICRO-1000 dataloggers. See the following
sections explaining how each mode operates.
Figure 3 illustrates the DIP switch SW1 position 1 for switching between 16 and 32
channel operation. SW1 switch 1 ON = 32 channel, OFF = 16 channel. In Figure 3, 32
channel mode is chosen:
Figure 3 - 16 or 32 Channel Selection
ON
OFF
SW1
1
2
3
4