Campbell CR200 Uživatelský manuál Strana 5

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 8
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 4
5
Compatible Sensors**
e CR200-series loggers can measure a variety of sen-
sors including SDI-12 sensors and 4 to 20 mA sensors.
e parameters and sensors in which the CR200-series
dataloggers can measure are listed below:
AC Current—CS15 Current Transformer. Our
CS10 is not compatible.
Barometric Pressure—CS100 and CS106 baro-
metric pressure sensors.
Evaporation —255-100 Evaporation Gauge.
Leaf Wetness—237 and LWS leaf wetness sensors.
Multiparameter —WXT520 Weather Transmitter.
Precipitation TE525, TE525WS, TE525MM,
TB4, TB4MM, CS700, and 385 tipping bucket
rain gages.
Relative Humidity—CS215, HMP50, and HMP45C
air temperature and relative humidity probes.
Snow Depth—SR50A Sonic Ranging Sensor.
Soil Volumetric Wate r Content— EasyAG probe,
EnviroSMART probe, and CS625 re ectometer.
Our CS616 and Hydrosense are not compatible.
Solar Radiation—CS300 Pyranometer. Our
LI200X, LI190SB, LP02, CMP3, NR-LITE, NR01,
CNR1, and CNR2 probes are not compatible.
Te m p e ra t u r e —109 Temperature Probe and 109SS
Temperature Probe for Harsh Environments.
Other temperature probes listed on our price lists
including our 107/108 thermistors and thermo-
couples are not compatible.
Water Level— CS408, CS450, CS455, and CS460
pressure transducers; CS410 Sha Encoder; CS470
and CS471 compact bubblers; CS475, CS476,
and CS477 pulse radar sensors, and SR50A Sonic
Ranging Sensor. Our CS431 pressure transducer
and DB1 Double Bubbler are not compatible.
Water Quality—CS525 ISET pH probe, OBS-3+
T
urb
idity Probe, CS511 Dissolved Oxygen Probe, 109
Temperature Probe, and 109SS Temperature Probe
for Harsh Environments. Our CS547A, CSIM11, and
CSIM11-ORP probes are not compatible.
Wind Speed and Direction—014A, 034B,
03101, 03002, 05103, 05106, 05305, and
WindSonic4 sensors. The WindSonic1 and
CSAT3 are not compatible.
Sensors Developed for CR200-series Dataloggers
** e CR200-series dataloggers cannot make di erential measurements and are not compatible with the fuel moisture/temperature, geographic
position, present weather, soil heat  ux, soil matric water potential, strain, and surface temperature sensors listed on our price lists. Campbell
Scienti cs SDM devices and multiplexers are also not supported.
CS625
CS625
The CS15 consists of a CR Magnetic’s CR8459
Current Transformer that was modi ed to measure
the approximate current over a 0 to 125 A range.
The CS625 Water Content
Re ectometer has a 0 to 3.3 V
square wave frequency output.
The 109 thermistor can measure air, water, or
soil temperature from -50° to +70°C. This probe
outputs a signal of 0 to 2.2 volts.
Zobrazit stránku 4
1 2 3 4 5 6 7 8

Komentáře k této Příručce

Žádné komentáře