CR200-series Datalogger Speci cations
Electrical speci cations are valid over a -40° to +50°C range unless otherwise speci ed; non-condensing environment required. We recommend
that you con rm system con guration and critical speci cations with Campbell Scienti c before purchase.
ANALOG INPUTS; DIGITAL I/O
Channels SE1 to SE5 can be individually configured
for single-ended measurement or digital I/O.
SINGLE-ENDED MEASUREMENT (SE1 TO SE5):
Analog Input Range: 0 V < 2.5 Vdc
Measurement Resolution: 0.6 mV
Measurement Accuracy
Typical: ±(0.25% of reading + 1.2 mV offset)
over -40° to +50°C
Worst-case: ±(1% of reading + 2.4 mV offset)
over -40° to 50°C
DIGITAL I/O (SE1 TO SE5):
Input/Output High State: 2.1 to 3.3 Vdc
Input/Output Low State: <0.9 Vdc
Output High State: 3.3 V (no load)
Drive Current: 220 µA @ 2.7 Vdc
Maximum Input Voltage: 4 Vdc
HALF BRIDGE MEASUREMENTS:
Accuracy: Relative to the excitation.
Using +2.5 Vdc excitation, is
±(0.06% of reading + 2.4 mV)/(2.5 Vdc)
PERIOD AVERAGING (SE1 TO SE4):
Maximum Input Voltage: 4 Vdc
Frequency Range: 0 to 150 kHz
Voltage Threshold: counts cycles on transition
from <0.9 Vdc to >2.1 Vdc
EXCITATION CHANNELS (EX1 AND EX2):
Range: Programmable 0, 2.5, 5 Vdc, or
off (floating)
Accuracy: ±25 mV on +2.5 Vdc range, ±125 mV
on +5.0 Vdc range
Maximum Current: 25 mA on +2.5 Vdc range,
10 mA on +5.0 Vdc range
CONTROL PORTS (C1 AND C2)
DIGITAL I/O:
Voltage Level When Configured as Input:
<0.9 Vdc (low state) to >2.7 Vdc (high state)
Voltage Level When Configured as Output:
0 V (low state), 5 Vdc (high state) (no load)
Logic Level: TTL
Drive Current: 1.5 mA @ 4.5 V
SDI-12: SDI-12 sensors connect to C1
PULSE COUNTERS
SWITCH CLOSURE (P_SW):
Maximum Count Rate: 100 Hz
Minimum Switch Open Time: 5 ms
Minimum Switch Closed Time: 5 ms
Maximum Bounce Time: 4 ms
PULSE COUNT (P_SW, C1, AND C2):
Voltage Threshold: count on transition from
<0.9 V to >2.7 Vdc
Minimum Pulse Width: 320 µs
Maximum Input Frequency: 1 kHz
Max Input Voltage: C1 & C2 (6.5 V), P_SW (4 Vdc)
LOW LEVEL AC (P_LL):
Voltage Threshold: <0.5 to >2 V
Minimum Input: 20 mV RMS
Maximum Frequency: 1 kHz
Maximum Input: ±20 V
Note: C1 and C2 can be used for switch closure
using the battery voltage and a 100 kOhm
pull-up resistor. If the dc offset is >0.5 V, then
AC coupling is required.
COMMUNICATIONS
SERIAL INTERFACE: Female RS-232 9-pin
interface for logger-to-PC communications
ON-BOARD SPREAD SPECTRUM RADIO:
Frequency: 915 MHz (CR206), 922 MHz (CR211),
or 2.4 GHz (CR216)
Transmission Range: 1 mile with 0 dBd ¼ wave
antenna (line-of-sight) and 900 MHz radios;
0.6 miles (1 km) with 0 dBd ½ wave antenna
(line-of-sight) and 2.4 GHz radio;
up to 10 miles with higher gain antenna
(line-of-sight)
RF4XX used as a base station radio
AVAILABLE RADIO TRANSMISSION MODES:
Always on, program controlled
Cycle Time: 1 or 8 s cycles; on for 100 ms every
period; checks for incoming communication
Scheduled Transmission Time: off until transmis-
sion time
P
AKBUS
®
packet switching network protocol
CLOCK ACCURACY
8.2 minutes/month @ -40° to +50°C; 1 minute/month
@ +25°C
CPU AND STORAGE
FINAL STORAGE: 512 kbyte Flash, data format
is 4 bytes per data point (table-based)
PROGRAM STORAGE: 6.5 kbyte Flash
FASTEST SCAN RATE: once per second
SWITCHED BATTERY (SW BATTERY)
Switched under program control; 300 mA minimum
current available
POWER
BATTERY VOLTAGE RANGE: 7 to 16 Vdc (can
program datalogger to measure internal battery
voltage)
MAX. CONTINUOUS BATTERY CHARGING
CURRENT:
0.9 A @ 20°C; 0.65 A @ 50°C
RECOMMENDED BATTERIES: 12 Vdc, 7 Ahr or
smaller sealed rechargeable battery when
connected to the on-board charging circuit.
Using larger batteries with the datalogger's
built-in charger may result in excessive PC
board heating. This is especially a concern
when the battery is deeply discharged or failing
with a shorted cell.
Alkaline cells, lithium, or other non-rechargeable
battery types may be connected if the charging
circuit is not used (i.e., nothing connected to
Charge terminals).
CHARGER INPUT VOLTAGE: 16 to 22 Vdc
SOLAR PANEL: 10 W or smaller when using
on-board charging circuit.
WALL CHARGER: 1 A or smaller when using on-
board charging circuit.
SHELF LIFE OF CLOCK’S BACKUP BATTERY:
5 years
CURRENT DRAIN (@12 V)
QUIESCENT CURRENT DRAIN:
No Radio or Radio Powered Off: ~0.2 mA
ACTIVE CURRENT DRAIN:
No radio ~3 mA
Radio receive ~20 mA (CR206, CR211),
~36 mA (CR216)
Radio transmit ~75 mA (CR206, CR211, CR216)
AVERAGE CONTINUOUS CURRENT DRAIN:
Radio always on ~20 mA (CR206, CR211),
~36 mA (CR216)
Radio in 1 s duty cycle ~2.2 mA (CR206,
CR211), ~4 mA (CR216)
Radio in 8 s duty cycle ~0.45 mA (CR206,
CR211), ~0.8 mA (CR216)
CE COMPLIANCE (as of 03/02)
CE COMPLIANT DATALOGGERS: CR200, CR206,
CR211, CR216
STANDARD(S) TO WHICH CONFORMITY IS
DECLARED: IEC61326:2002
EMI AND ESD PROTECTION
IMMUNITY: Meets or exceeds following standards:
ESD: per IEC 1000-4-2; ±8 kV air, ±4 kV contact
discharge
RF: per IEC 1000-4-3; 3 V/m, 80-1000 MHz
EFT: per IEC 1000-4-4; 1 kV power, 500 V I/O
Surge: per IEC 1000-4-5; 1 kV power and I/O
Conducted: per IEC 1000-4-6; 3 V 150 kHz-80 MHz
Emissions and immunity performance criteria avail-
able on request.
PHYSICAL
CASE DESCRIPTION: Aluminum with spring-loaded
terminals
DIMENSIONS (including terminals): 5.5” x 3” x 2”
(14.0 x 17.6 x 5.1 cm)
WEIGHT:
CR200 or CR295: 8.5 oz (242 g)
CR206, CR211, or CR216: 9.5 oz (271 g)
CUSTOM CASE: available for OEM applications;
contact Campbell Scientific
WARRANTY
One year covering parts and labor.