CS450/CS455 Pressure
Transducer
Revision: 1/12
Copyright © 2009-2012
Campbell Scientific, Inc.
Zobrazit stránku 0
1 2 3 4 5 6 ... 33 34

Shrnutí obsahu

Strany 1 - Transducer

CS450/CS455 Pressure TransducerRevision: 1/12Copyright © 2009-2012Campbell Scientific, Inc.

Strany 2

CS450/CS455 Pressure Transducer 3.1 Connection Communicating with the CS450/CS455 requires the sensor to be either connected to a PC or to an SDI-12

Strany 3 - Warranty

CS450/CS455 Pressure Transducer To check which COM port has been assigned to the A200, you can monitor the appearance of a new COM port in the list of

Strany 4 - Assistance

CS450/CS455 Pressure Transducer 3.1.2 Device Configuration Utility (version 1.12 or higher) The Device Configuration Utility (DevConfig) allows you t

Strany 5

CS450/CS455 Pressure Transducer FIGURE 3-3. Connect screen There are three settings that can be changed: SDI-12 address, Pressure/Level Units and Te

Strany 6

CS450/CS455 Pressure Transducer 3.1.3 SDI-12 Transparent Mode Transparent Mode allows direct communication with the CS450/CS455. This may require w

Strany 7 - 1. Introduction

CS450/CS455 Pressure Transducer responds with a prompt. CR10X and CR510 dataloggers reply with “entering SDI-12”. CR10X-PB and CR510-PB dataloggers r

Strany 8 - 2. Specifications

CS450/CS455 Pressure Transducer FIGURE 3-6. HyperTerminal TABLE 3-4. RS-232 Terminal Commands Terminal Commands Values Returned 1 Serial Number,

Strany 9 - 3. Configuration

CS450/CS455 Pressure Transducer 3.2 SDI-12 Commands The CS450/CS455 uses an SDI-12 compatible hardware interface and supports a subset of the SDI-12

Strany 10 - 3.1 Connection

CS450/CS455 Pressure Transducer The CS450/CS455 is shipped from the factory with the address set to 0. The address on the CS450/CS455 can be changed b

Strany 11

CS450/CS455 Pressure Transducer Only SDI-12 instruction aM!, aM7!, and aM8! output the results obtained when using the multiplier and offset. The offs

Strany 13

CS450/CS455 Pressure Transducer Pressure can be converted to feet of fresh water using the following simple equation: 1 psi = 2.31 feet of water For e

Strany 14

CS450/CS455 Pressure Transducer For example, if the correct elevation of the water, as measured by a staff gauge or other measurement device, is 2015.

Strany 15

CS450/CS455 Pressure Transducer 5.2 RS-232 TABLE 5-2. RS-232 Wiring Color CS450/CS455 Function Connection RS-232 9-pin Red +12vdc Power Source

Strany 16

CS450/CS455 Pressure Transducer Sample Program for CR200 Series Datalogger ‘CR200 Series ‘Declare the variable for the water level measurement Public

Strany 17 - 3.2 SDI-12 Commands

CS450/CS455 Pressure Transducer ‘Read sensor every 60 seconds BeginProg Scan(60,sec,1,0) ‘Code for SDI-12 measurements: SDI12Recorder(CS450,1,

Strany 18

CS450/CS455 Pressure Transducer ;{CR10X} ; *Table 1 Program 01: 60 Execution Interval (seconds) 1: SDI-12 Recorder (P105) 1: 0 SDI-12 Addres

Strany 19 - 4. Installation

CS450/CS455 Pressure Transducer 7.1 Every Visit • Collect data • Visually inspect wiring and physical conditions • Check indicating desiccant or e

Strany 20 - 4.6 Calculate Offset

CS450/CS455 Pressure Transducer Suggestion: A kinked or plugged vent tube will not effectively vent a gauge pressure (Vented) type of device. Normal c

Strany 21 - 5. Wiring

CS450/CS455 Pressure Transducer 22

Strany 22 - 6. Programming

Appendix A. Calibration Certificate Each CS450/CS455 has been calibrated to meet printed accuracy specification at multiple temperature and pressure

Strany 23

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Strany 24 - 6.2.2 Edlog Programming

Appendix A. Calibration Certificate A-2

Strany 25 - 7. Maintenance

Appendix A. Calibration Certificate bars = kPa / 100.0 psi = kPa * 0.145 FIGURE A-1. Calibration certificate A-3

Strany 26 - 8. Troubleshooting

Appendix A. Calibration Certificate A-4

Strany 28

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strany 29

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strany 30

CS450/CS455 Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for li

Strany 31

CS450/CS455 Table of Contents ii 7. Maintenance ...19 7.1 Every Visit ...

Strany 32

CS450/CS455 Pressure Transducer The CS450/CS455 Submersible Pressure Transducer probe is designed for general pressure measurements. It utilizes the S

Strany 33

CS450/CS455 Pressure Transducer The model number and pressure range is etched on the housing. Check this information against the shipping documentatio

Strany 34

CS450/CS455 Pressure Transducer Compensated Temperature: 0 to 60°C Temperature Accuracy: ±0.2°C Maximum Cable Length: SDI-12 - one sensor connected