Campbell NL115 Manuál Strana 1

Procházejte online nebo si stáhněte Manuál pro Sítě Campbell NL115. Campbell NL115 Product manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - CompactFlash

NL115 Ethernet andCompactFlash® ModuleRevision: 12/11Copyright © 2006-2011Campbell Scientific, Inc.

Strany 2

Section 1. NL115 Ethernet/CompactFlash® Module Overview 1.5.2 Communicating via Ethernet Step 1 – Configure Datalogger a. Connect serial cable from

Strany 3 - Warranty

Section 1. NL115 Ethernet/CompactFlash® Module Overview Step 2 – LoggerNet Set-up The next step is to run LoggerNet and configure it to connect to th

Strany 4 - Assistance

Section 1. NL115 Ethernet/CompactFlash® Module Overview Step 3 – Connect You are now ready to Connect to your datalogger using the LoggerNet Connect

Strany 5 - NL115 Table of Contents

Section 1. NL115 Ethernet/CompactFlash® Module Overview 1.5.4 Data Retrieval Data stored on cards can be retrieved through a communication link to t

Strany 6

Section 1. NL115 Ethernet/CompactFlash® Module Overview 1-8

Strany 7 - Module Overview

Section 2. TCP/IP Functionality This section describes the main TCP/IP functionality of a datalogger with an NL115 attached. Additional functionalit

Strany 8 - 1.2 Physical Description

Section 2. TCP/IP Functionality BeginProg Scan (5,Sec,6,0) PanelTemp (PanelTemperature,250) Battery (BatteryVoltage) If not Route(4094) t

Strany 9 - 1.5 Quick Start Procedure

Section 2. TCP/IP Functionality BeginProg Scan(2,Sec,0,0) Socket = TCPOpen(“192.168.7.125”,6785,0) BatteryVoltage(BattVolt) PanelTemp(PTe

Strany 10

Section 2. TCP/IP Functionality FIGURE 2-1. Datalogger Home Page If there is a default.html file on the datalogger, this will automatically become

Strany 11 - Step 2 – LoggerNet Set-up

Section 2. TCP/IP Functionality FIGURE 2-2. FTP Root Directory FIGURE 2-3. FTP CRD Directory 2-5

Strany 13 - 1.5.4 Data Retrieval

Section 2. TCP/IP Functionality In order to use FTP, the datalogger’s FTP User Name and FTP Password must be set. This is done using Device Configur

Strany 14

Section 2. TCP/IP Functionality PROGRAM ' CR1000 ' FTPClient.cr1 Public Result1, Result2 BeginProg Scan (20,Sec,1,1) Result1 = FTPCl

Strany 15 - 2.1.1 Data Call-back

Section 2. TCP/IP Functionality returned by the TCPOpen instruction. The third parameter is the timeout. The fourth parameter is the termination ch

Strany 16

Section 2. TCP/IP Functionality 2.9 DNS The datalogger provides a DNS client that can query a DNS server to resolve a fully qualified domain name.

Strany 17 - 2.2 HTTP Web Server

Section 2. TCP/IP Functionality 2-10

Strany 18 - 2.3 FTP

Section 3. File Formats This section covers the different types of files stored on the CF card. 3.1 Data Files The datalogger stores data on the CF

Strany 19

Section 3. File Formats Test the power-up functions in the office before going into the field to ensure the power-up file is configured correctly. C

Strany 20 - Step 2 – Access File System

Section 3. File Formats TABLE 3.3.1-1. Powerup.ini Commands Command Description 1 Run always, preserve CF data files 2 Run on power-up 5 Format 6

Strany 21 - 2.6 Serial Server

Section 3. File Formats 3.3.3 Program Execution After File is processed, the following rules determine what datalogger program to run: 1) If the Ru

Strany 22 - 2.8 DHCP

Section 3. File Formats 3.4 Camera Files JPEG images taken by a digital camera connected to the datalogger can be stored to the CF card rather than

Strany 23 - 2.9 DNS

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Strany 24

Section 3. File Formats 3-6 This is a blank page.

Strany 25 - Section 3. File Formats

Section 4. Programming 4.1 The CardOut Instruction The CardOut Instruction is used to send data to a CF card. The CardOut Instruction must be enter

Strany 26

Section 4. Programming BeginProg Scan(1,SEC,3,0) PanelTemp(temp,250) CallTable Table1 NextScan EndProg 4.2.2 Fill and Stop Mode The followin

Strany 27 - 3.3.2 Applications

Section 4. Programming these tables, once space for the fixed-size tables has been allocated. The datalogger will attempt to size the tables so that

Strany 28 - 3.3.3 Program Execution

Section 4. Programming 4-4 4.3 Table Size and Mode The size of each data table in CPU memory is set as part of the DataTable instruction and the siz

Strany 29 - 3.4 Camera Files

Section 5. Data Retrieval Data stored on CF cards can be retrieved through a communication link to the datalogger or by removing the card and carryin

Strany 30 - This is a blank page

Section 5. Data Retrieval 5.2 Transporting CF Card to Computer With large files, transferring the CF card to a computer may be faster than collectin

Strany 31 - Section 4. Programming

Section 5. Data Retrieval 5.2.2 Reinserting the Card If the same card is inserted again into the NL115, the datalogger will store all data to the c

Strany 32 - 4.2.3 Mixed Modes

Section 5. Data Retrieval 5-4 3. When ready to retrieve data, press NL115 button to remove card. LED will show red while the most current data is s

Strany 33

Appendix A. Formatting CF Card The CF card can be formatted using 1) Windows Explorer, 2) the CR1000KD or 3) LoggerNet File Control. A.1 Windows Exp

Strany 34 - 4.3 Table Size and Mode

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strany 35 - Section 5. Data Retrieval

Appendix A. Formatting CF Card 5) Choose FAT32 under file system, give the card a label, then Start. (The datalogger will work with either FAT or F

Strany 36

Appendix A. Formatting CF Card 3) Choose FileControl under the Tools menu of the Connect screen. 4) Highlight CRD. 5) Press Format. 6) Press Yes

Strany 37 - 5.2.3 Card Swapping

Appendix A. Formatting CF Card A-4 This is a blank page.

Strany 38

Appendix B. PC/CF Card Information PC or CompactFlash (CF) cards provide a relatively inexpensive, off-the-shelf means of retrieving data from many o

Strany 39 - A.1 Windows Explorer

Appendix B. PC/CF Card Information found that SLC outperformed MLC, offering greater durability, running 300% faster in write mode, and 43% faster in

Strany 40 - A.3 LoggerNet File Control

Appendix B. PC/CF Card Information References 1. “Implementing MLC NAND Flash for Cost-Effective, High-Capacity Memory”, written by Raz Dan and Roch

Strany 41

Appendix B. PC/CF Card Information B-4

Strany 43

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strany 44

NL115 Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to

Strany 45

NL115 Table of Contents ii 4. Programming... 4-1 4.1 The CardOut Instruction ...

Strany 46

Section 1. NL115 Ethernet/CompactFlash® Module Overview Campbell Scientific's NL115 Ethernet/CompactFlash® Module provides two independent capab

Strany 47

Section 1. NL115 Ethernet/CompactFlash® Module Overview Software Requirements: LoggerNet 3.2 or later PC400 1.3 or later Dimensions: 4.0" x

Strany 48

Section 1. NL115 Ethernet/CompactFlash® Module Overview 1.3 Power 1.3.1 Primary Power The Ethernet/CompactFlash Module is powered by 12 VDC receive

Komentáře k této Příručce