Campbell SDM-CAN Specifikace

Procházejte online nebo si stáhněte Specifikace pro Sítě Campbell SDM-CAN. Campbell SDM-CAN Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Input/Output Module

SDM-SIO1 SerialInput/Output Module3/08Copyright © 2008Campbell Scientific, Inc.

Strany 2 - Warranty and Assistance

SDM-SIO1 Serial Input/Output Module There can be up to 15 SDM-SIO1s on a single SDM bus. Each SDM-SIO1 will need to have a unique address before they

Strany 3 - SDM-SIO1 Table of Contents

SDM-SIO1 Serial Input/Output Module When making connections to the datalogger always insure power to the datalogger is switched off and connect the gr

Strany 4 - Appendix

SDM-SIO1 Serial Input/Output Module (3) There is a 100R resistor in series with the datalogger’s ground connection. This connection should be used whe

Strany 5 - 1. Introduction

SDM-SIO1 Serial Input/Output Module 3.3 Examples for Connecting the SDM-SIO1 to Other Equipment 3.3.1 RS-485 One to One Connection Example 1 C1

Strany 6 - 2. Specifications

SDM-SIO1 Serial Input/Output Module 3.3.2 RS-485 Multi Unit / In Line Example 1 C1 2 C2 RS-485 0V for ground referencing 3 C3

Strany 7 - 2.2 Electrical Parameters

SDM-SIO1 Serial Input/Output Module 3.3.3 RS-485 Half Duplex Wiring Example 1 C1 2 C2 3 C3 To logger 4 G

Strany 8 - 2.2.3 EMC Compliance

SDM-SIO1 Serial Input/Output Module 3.3.5 RS-232 Wiring Example with Handshaking 1 C1 2 C2 3 C3 To logger 4 G

Strany 9 - 3. Installation

SDM-SIO1 Serial Input/Output Module 3.3.7 Connecting a 9-Way Socket to the SDM-SIO1 1 C1 2 C2 3 C3 To logger 4 G

Strany 10 - 3.1 Connections

SDM-SIO1 Serial Input/Output Module sends data one-way to the datalogger, run the SDM-SIO1 in “receive only mode” as this does not turn on the output

Strany 11

SDM-SIO1 Serial Input/Output Module TABLE 4-1. Communications Port Parameters RS-232 Code Parity No. Stop Bits No. Data Bits 0 None 1 8 1 Odd 1

Strany 12 - 3.2 Safety Considerations

Warranty and Assistance The SDM-SIO1 SERIAL INPUT/OUTPUT MODULE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and wor

Strany 13 - Equipment

SDM-SIO1 Serial Input/Output Module TABLE 4-3. Communications Port Parameters RS-485 Half Duplex Code Parity No. Stop Bits No. Data Bits 48 None

Strany 14

SDM-SIO1 Serial Input/Output Module 4.1.2 SerialClose This will place the SDM-SIO1 unit into shutdown mode where only SDM communications will operate

Strany 15

SDM-SIO1 Serial Input/Output Module 4.1.6 SerialOutBlock No special information. This can also be used to set the general purpose output line (see Ap

Strany 16

SDM-SIO1 Serial Input/Output Module Enabling handshaking will increase active current consumption due to the extra RS-232 load. It will not affect sle

Strany 17 - 3.4 Power Conservation

SDM-SIO1 Serial Input/Output Module 4.3.1 Example Using RS-232 Mode '----------------------------------------------------------------------- &ap

Strany 18 - 4.1.1 SerialOpen

SDM-SIO1 Serial Input/Output Module 4.3.2 Example Using RS-485 Mode '----------------------------------------------------------------------- &ap

Strany 19

SDM-SIO1 Serial Input/Output Module 22 5. Firmware Upgrades and Flash Signature Errors 5.1 Upgrading the Firmware Firmware upgrades can be done by c

Strany 20

Appendix A. Using the Handshaking Lines for General Input/Output This Appendix describes how to use the CTS and RTS lines for input and output ports.

Strany 21 - 4.1.2 SerialClose

Appendix A. Using the Handshaking Lines for General Input/Output ‘IF value returned is over 4095 then input line is high ‘ELSE input line must be

Strany 22

Appendix A. Using the Handshaking Lines for General Input/Output Value of ‘SerialOutBlock’‘SerialExpression’ variable Voltage on the output line 1

Strany 23

SDM-SIO1 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab

Strany 24

Appendix A. Using the Handshaking Lines for General Input/Output A-4

Strany 25

This is a blank page.

Strany 26 - 5.1 Upgrading the Firmware

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Strany 27 - A.1 The Input Pin (Pin 8)

SDM-SIO1 Table of Contents ii 4.3 Example Datalogger Programs ... 19 4.3.1 Example Using

Strany 28 - A.2 The Output Pin (Pin 9)

SDM-SIO1 Serial Input/Output Module The SDM-SIO1 Module is designed to allow expansion of the number of serial ports available on a datalogger for com

Strany 29

SDM-SIO1 Serial Input/Output Module 2. Specifications 2.1 Supported Data Rates and Protocols Data rates and protocols are set up using the SerialOpe

Strany 30

SDM-SIO1 Serial Input/Output Module 2.2 Electrical Parameters 2.2.1 SDM-SIO1 Current Consumption Nominal Max Notes General Currents Standby current

Strany 31 - This is a blank page

SDM-SIO1 Serial Input/Output Module 2.2.2 SDM-SIO1 Voltage Specifications Connection Minimum Voltage(1) Nominal Voltage(1) Maximum Voltage(1) Power

Strany 32

SDM-SIO1 Serial Input/Output Module 2.3 Temperature and Humidity Ranges Temperature Range Minimum Maximum Notes Standard range -20ºC +50ºC Ext

Komentáře k této Příručce

Žádné komentáře