Campbell TX320 Uživatelský manuál Strana 5

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 8
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 4
The CR200X-series dataloggers can measure a variety of sensors in-
cluding SDI-12 sensors and 4 to 20 mA sensors. The parameters and
sensors in which the CR200X series can measure are listed below:
AC Current—CS11 Current Transformer.
Barometric Pressure—CS100, CS106, and 092 barometers.
Evaporation—255-100 Evaporation Gauge.
Leaf Wetness—237 and LWS leaf wetness sensors.
Multiparameter—WXT520 Weather Transmitter.
PrecipitationTE525, TE525WS, TE525MM, TB4, TB4MM, CS700,
and 52202 tipping bucket rain gages.
Relative Humidity—CS215, HMP60, HC2S3, 083E, and HMP155A
air temperature and relative humidity probes.l
Snow Depth—SR50A Sonic Ranging Sensor.
Soil Volumetric Water Content— EasyAG probe, EnviroSCAN
probe, CS650 reectometer, and CS625 reectometer.
Our CS616
is not compatible
.
Solar RadiationCS300 Pyranometer.
Our LI200X, LI190SB, LP02,
CMP3, CMP6, CMP11, CMP21, NR-LITE2, NR01, and CNR4 probes
are not compatible
Temperature—109, 109SS, and 110PV thermistors.
Other tem-
perature probes listed on our price lists including our 107/108
thermistors and thermocouples are not compatible
.
Water Level—CS451, CS456, and CS460 pressure transducers;
CS410 Shaft Encoder; CS470 and CS471 compact bubblers;
CS475, CS476, and CS477 pulse radar sensors, and SR50A Sonic
Ranging Sensor.
Water Quality—OBS-3+ turbidity probe, OBS300 turbidity probe,
OBS500 turbidity probe with antifouling features, CS511 Dissolved
Oxygen Probe, 109 Temperature Probe, and 109SS Temperature
Probe.
Our CS526, CS547A, CSIM11, CSIM11-ORP, 107, and 108
probes are not compatible.
Wind Speed and Direction—014A, 034B, 03101, 03002, 05103,
05106, 05305, 27106T, and WindSonic4 sensors. T
he WindSonic1,
CSAT3, and Zephir300 are not compatible.
Compatible Sensors
4
4
e CR200X-series dataloggers can not make dierential measurements. ey are not compatible with the freezing-rain/ice, fuel moisture/temperature,
geographic position, present weather, soil heat ux, snow water equivalent, soil matric water potential, strain, and visibility sensors listed on our price lists.
Campbell Scientics SDM devices and multiplexers are also not supported.
The CS625 Water Content Reectometer has a 0 to 3.3 V square wave frequency output.
The 109 thermistor can measure air, water, or soil temperature
from -50° to +70°C. This probe outputs a signal of 0 to 2.2 V.