Campbell Met One 034A-L Návod k obsluze Strana 33

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 75
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 32
33
Manual
Power Supply
4.2.2 Installing/Changing the Battery
The PS12-LA power supply housing forms the battery holder. It is shown on figure 12, together with other elements
of the power supply.
Follow the below specified guidelines to replace the battery:
• DetachthecoverofthePS12-LAhousingbyunscrewingthetwoscrewonbothsidesofthecap;
• DisconnectpowertothedataloggerbytogglingtheswitchtoOFF;
• ClipoffthebatteryconnectorfromtheterminalINT;
• Takeoutthebattery;
• Putinthenewbattery,makesurethebatteryterminalsareonthesideoftheregulator;
• PlugthebatteryconnectorintotheINTterminal,makesuretheclipisproperlyattached;
• ReconnectpowertothedataloggerbytogglingtheswitchtoON;
• Replacethecover.
Figure 12: PS12-LA Power Supply for CR10X Storage and Control Module
INT Battery Terminal
Charging Indicator
ON/OFF Switch
Input Terminals Solar
Power Supply
12V Terminals to CR10X
Battery Connected to PS12LA Regulator
Rechargeable Battery
PS12LA Housing
Zobrazit stránku 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 74 75

Komentáře k této Příručce

Žádné komentáře