Appendix F. CR510PB w/ P193 Master to CR205s Network
F-4
SendGetData (HostResponse,host(),Remote(),1,100,100,0) 'Host
response of 0 = success
Endif
CallTable(Table1)
NextScan
EndProg
5. Save the program as WIRELESS.CR2 and compile it.
6. Using PakCom (or LoggerNet), send WIRELESS.bin to each CR205 in
network.
7. Connect power supply and antenna to each CR205.
CR510PB Settings and Program
1. In Edlog key in the following program:
*Table 1 Program
01: 20 Execution Interval (seconds)
1: Batt Voltage (P10)
1: 1 Loc [ Battery ] ; Fill Input Locs 1 to 3
2: Internal Temperature (P17)
1: 2 Loc [ Panel_Temp ]
3: Z=F x 10^n (P30)
1: 123 F
2: 0 n, Exponent of 10
3: 3 Z Loc [ Number ]
4: Data Table (P84)
1: 0 Seconds into Interval
2: 60 Seconds Interval
3: 0 (0 = auto allocate, -x = redirect to inloc x)
4: Transfer Table Name
5: Average (P71)
1: 1 Reps
2: 1 Loc [ Battery ]
6: Average (P71)
1: 1 Reps
2: 2 Loc [ Panel_Temp ]