AM16/32B Relay Analog Multiplexer
Weight:
1.5 lbs. (approx.), 693 g.
Mounting Tab
Hole Spacing:
1 inch x 3 inches x 9 inches. Up to 1/8 inch or 3
mm diameter screws (see Figure 22).
Expandability
**
(nominal):
2 AM16/32Bs per CR800/CR850
4 AM16/32Bs per CR3000
4 AM16/32Bs per CR5000
4 AM16/32Bs per CR1000
4 AM16/32Bs per CR23X
4 AM16/32Bs per CR10(X)
4 AM16/32Bs per 21X
8 AM16/32Bs per CR7 725 Card
Maximum Cable
Length:
Depends on sensor and scan rate. In general, longer
lead lengths necessitate longer measurement delays.
Refer to datalogger manual for details.
Maximum Switching
Current
***
:
500 mA
Contact
Specifications:
Initial contact resistance: <0.1 ohm max.
Initial contact bounce: <1 ms
Contact material: Gold clad silver alloy
Wiper to N.O. contact capacitance: 0.5 pF
Typical low-current (<30 mA) life: 5 x 10
7
operations
Relay Switching
Thermal emf: 0.3 µV typical; 0.5 µV maximum
Characteristics
(applying 11.3 – 14
VDC):
Operate time: <10 ms over temperature and supply
ranges
Break-before-make guaranteed by design.
Relays disengage from previous selected channel
before engaging next channel.
ESD:
Air Discharge: complies with IEC61000-4-2, test
level 4 (±15 kV)
Contact Discharge: complies with IEC61000-4-2,
test level 4 (±8 kV)
Surge:
Complies with IEC61000-4-5, test level 3 (±2 kV,
2 ohms coupling impedance)
*
Reset and clock protected by 8V varistors; +12V input is protected by +16V transzorb.
**
Assumes sequential activation of multiplexers and that each datalogger channel is uniquely
dedicated. If your application requires additional multiplexing capability, please consult CSI for
application assistance.
***
Switching currents greater than 30 mA (occasional 50 mA current is acceptable) will degrade
the contact surfaces of the mechanical relays (increase their resistance). This will adversely affect
the suitability of these relays to multiplex low voltage signals. Although a relay used in this
manner no longer qualifies for low voltage measurement, it continues to be useful for switching
currents in excess of 30 mA.