APPENDIX G. CALLBACK (CR23X INITIATED TELECOMMUNICATIONS)
G-6
8: If Flag/Port (P91) ;Enable Cell Transceiver if No Alarm
1: 11 Do if Flag 1 is High
2: 30 Then Do
9: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 41 Set Port 1 High
10: If time is (P92)
1: 10 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 51 Set Port 1 Low
11: End (P95)
12: If Flag/Port (P91) ;Enable Cell Transceiver if Alarm
1: 21 Do if Flag 1 is Low
2: 30 Then Do
13: Do (P86)
1: 41 Set Port 1 High
14: End (P95)
;*****************************************************
15: Initiate Telecommunications (P97)
1: 21 Phone Modem/1200 Baud<<<<<<<<<<<Note Device / Baud Code
2: 1 Disabled when User Flag 1 is High
3: 120 Seconds Call Time Limit
4: 0 Seconds Before Fast Retry
5: 0 Fast Retries
6: 0 Minutes before Slow Retry
7: 3 Failures Loc [ Failures ]
8: 123 Call-back ID
16: Extended Parameters 4 Digit (P68)
1: 1 Option ; First Digit of Computer's Phone Number
2: 4 Option
3: 3 Option
4: 5 Option
5: 1 Option
6: 2 Option
7: 3 Option
8: 4 Option
17: Extended Parameters 4 Digit (P68)
1: 5 Option
2: 6 Option
3: 7 Option
4: 13 Option ; ASCII Decimal Termination Character
5: 0 Option
6: 0 Option
7: 0 Option
8: 0 Option