AD-3-1
SECTION 3. INSTRUCTION SET BASICS
Section 3.7.1 does not apply to the TD operating system which does not use Output Flag 0.
Table 3.8-1 Valid Flag Commands are 11 – 19 to set high and 21- 29 to set low. Because the TD
operating system does not use Flag 0, Comm
ands 10 and 20 are not valid with the TD operating system.
The following table replaces Table 3.10-1 for the TD operating system.
T
ABLE 3.10-1. Error Codes
Code Type Description
03 Editor Program table full
04 Compile Intermediate Storage full
05 Compile Storage Area #2 not
allocated
08
Run Time CR10X reset by
watchdog tim
er
09 Run Time Insufficient Input Storage
10 Run Time Low Battery Voltage
11 Editor Attempt to allocate more
Input or Interm
ediate
Storage than is available
20 Compile SUBROUTINE encountered
bef
ore END of
previous
subroutine
21 Compile END without IF, LOOP or
SUBRO
UT
INE
22 Compile Missing END
23 Compile Nonexistent
SUBROUT
INE
24 Compile ELSE in SUBROUTINE
without IF
25
Compile ELSE without IF
26 Compile EXIT LOOP without
LOOP
27 Com
pile IF CASE without BEGIN
CASE
28 Compile At compile time, no
output s
pecif
ied after P84
or unable to automatically
allocate at least one
record per P84
29 Compile Output table requests
mo
re
memory than
available
30 Compile IF and/or LOOP nested
too deep
31 Run Time SUBROUTINES nested
too deep
32 Compile Instruction 3 and interrupt
s
ubroutine us
e same port
33 Compile Cannot use Control Port
6 as counter
or interrupt
subroutine with
Instruction 15 or SDM or
SDI-12 input/output
40 Editor Instruction does not exist
41 Editor Incorrect execution
inter
val
43
Compile Time in Instruction 84 or
92 is not a multiple of
ex
ecution interval (note:
time is in seconds)
44 Compile Loop (P87) cannot
c
ontain Data Table (
P84)
60 Compile Insufficient Input Storage
61 Compile Burst Measurement Scan
Rate too short
62
Compile N<2 in FFT
68 Compile Instruction 118 without
enough Instr
uctions 68 or 63
80 Compile Illegal Interval in P193
81 Compile Illegal Node ID in P193
82 Compile Illegal Reps in P193
92 Compile Instruction 92, intervals in
seconds
: Time into Interval
> 59 or Interval > 60
Komentáře k této Příručce