11
Figure 2: Workflow that illustrates the steps for siting the climate station. In Level 1, all sensors (precipitation,
temperature, relative humidity and solar radiation) are together at the same location. In Level 2, the station is sited
using the requirements of the temperature/RH and precipitation sensors and the radiation sensor is located at an
alternate point within 100 m of the climate station and connected to the same data logger. In Level 3 the radiation
sensor is located at a separate location (> 100 m away from the other sensors) and has a dedicated data logger and
power source, separate from the rest of the sensors. If no open areas are available that fulfill Level 2 siting then
locate the station in the site that most closely resembles Level 2 requirements and document site conditions carefully
(Level 4).