2.8 Level 4 Siting
In many sites it might be difficult to find an open area that complies with the requirements for
Level 1 (siting requirements for all three sensors are met) or Level 2 (siting requirements for
precipitation and temperature are met). In such cases, it is suggested that the station is located in
an open area that is the closest possible match to a Level 2 clearing (see Section 0) and that the
site conditions are carefully documented and monitored annually. In particular, watch for the
following:
Make sure the Temperature/RH sensor is as far as possible from surrounding vegetation
to minimize microclimatic conditions that could affect the readings.
Ensure that the precipitation gauge has a clear view of the sky and is as far as possible
from surrounding obstacles to avoid water ‘bouncing in’ from other sources, thus
contaminating the readings.
Locate the radiation sensor following the guidelines for Level 2 (within 100 m of the
climate station). If this is not feasible, install the radiation sensors as high as possible in
the current climate base and document carefully the site conditions.
Always document carefully the site conditions and monitor conditions annually.
2.9 Ordering The Equipment
Once an adequate siting strategy has been reached, the appropriate equipment can be ordered.
A standardized list of equipment is shown in Appendix A.1. Allow ample time (minimum of 4
weeks) for the equipment to arrive at customs in the destination country and an additional 4
weeks for clearing the equipment through customs and arriving at their destination.
3 Assembly of the Climate Station
This section describes the whole process of setting up the climate station from the moment the
equipment is received to a full test run of the climate station with all its sensors. The process is
outlined in general with the main steps; for details refer to the instruction manuals accompanying
the base tower, data logger and sensors.
3.1 Testing all the instrumentation upon receipt
Equipment/supplies needed:
Data logger (CR1000)
PC200W software (included with data logger)
Blank memory card
Battery (UB121000)
Two Temperature/RH sensors (HMP45C-L)
Two Solar Radiation sensors (LI200X-L)
Precipitation sensor (TB4MM-L)
Computer
Zobrazit stránku 16