Appendix A.1. Main Equipment List
(Continues into next page)
Category Equipment
Description
Number Supplier Model ID Level
1 &4
Level
2
Level
3
BASE 10ft Tripod with
Grounding Kit
1 Campbell
Scientific
CM10 Yes Yes Yes
DATA LOGGER Automated Data
Logger
1 Campbell
Scientific
CR1000 Yes Yes Yes
MEMORY CompactFlash
Module
1 Campbell
Scientific
CFM 1000 Yes Yes Yes
64 MB Memory
cards
2 SanDisk CFMC253M Yes Yes Yes
SENSORS Auto Precipitation
Gauge
1 Campbell
Scientific
TB4MM-L Yes Yes Yes
Temperature/ RH
sensor
2 Vaisala HMP45C-L Yes Yes Yes
Solar Radiation
Sensor -12 ft
cable
2 Licor LI-200X-L Yes No Yes
Solar Radiation
Sensor -300 ft
cable
2 Licor LI-200X-L No Yes No
ACCESSORIES Leveling Base for
TB4-L
1 Campbell
Scientific
CM-240 Yes Yes Yes
Leveling Base for
Licor
2 Campbell
Scientific
LI2003S Yes Yes Yes
Passive radiation
shield
1 Met One 41003-5 Yes Yes Yes
Weather-resistant
enclosure
1 Campbell
Scientific
ENC-14/16-C Yes Yes Yes
Sensor Cross arm 3 Campbell
Scientific
CM206 Yes Yes Yes
Solar Sensor
Mounting Stand
2 Campbell
Scientific
CM225 Yes Yes Yes
POWER 12 V battery - 100
Ah
1 Universal
Power
Group
UB121000 Yes Yes Yes
12V Charging
regulator
1 Morning
Star
PS100 Yes Yes Yes
10 W Solar Panel 1 Yingli SP10 Yes Yes Yes