Precipitation gauge Clean debris from collection funnel Every time station is visited
Clean/remove debris from inside
Make sure tipping bucket is working
Check level
Biweekly
Solar Radiation sensor Check level, remove debris, inspect
drain hole
Monthly
Solar Panel Clean surface, check voltage Every time station is visited,
Monthly
Battery Check cable connections Monthly
Inspect voltage logs Every time data is
downloaded
Table 6: Summary of maintenance activities for the equipment in the climate station.
4.7 Data Retrieval
Retrieving the data often is essential to detect any data anomalies and problems with the sensors.
There are several ways to retrieve data from the station, but here we only describe one option:
manually through removal of the memory card. We envision having wireless options for data
retrieval in the near future, either through radio, cell phone, or satellite uplink. Until then, it is
essential that data is retrieved every time the station is visited for maintenance.
4.8 Retrieving the Data Manually from the Field
Take a memory card: Take a blank, specially formatted memory card to replace the one that
will be retrieved.
Take out and replace the memory card: After opening the enclosure, extract the memory card
by first pressing the white button in front of the memory card adapter on the right side of the data
logger. As soon as it turns green, open the door of the adapter and push the button to eject the
memory card. Do not be concerned about losing any data when removing the card; the data
logger will keep collecting data, which will be stored in its internal memory. Put in the new
memory card and close the door of the adapter.
4.9 Extract the Climate Measurement Data File from the Memory Card
See instructions for creating a local storage directory and extracting Climate Measurement Data
files in Section 3.6.
4.10 Upload the data to the TEAM portal:
The Climate Measurement Data File should be uploaded to the TEAM Network portal. A fully
dynamic data management system for all Climate Protocol data and forms has been developed to
make it easy to share and store data. Upload the Climate Measurement data using the following
process:
a) Go the www.teamnetwork.org and log into the portal.
b) From the menu on the top of the home screen, hold your mouse over the “Products
link, so a drop down menu appears.