2. Install the memory card adaptor to the data logger: The memory card module is a
flattened box labeled CFM100. Plug it into the peripheral port of the data logger and
fasten the outside screw to secure it.
3. Insert a memory card into the CFM100: Unfasten the screw on the right hand side of
the CFM100 to open the door to the memory card compartment. Insert the special
memory card provided (regular memory cards will NOT work) in the slot. Close the
door to the compartment and tighten the screw.
4. Install the PC200W Campbell Software in your computer: This software is included
in a CD that came with the data logger and allows you to set the clock of the data logger
and upload the standard TEAM data collection program. Alternatively, if the CD is lost,
PC200W is also available on the Campbell Scientific website at:
http://www.campbellsci.com/pc200w.
5. Open the PC200W software: The data logger should now be on and waiting for
instructions on what to do. Launch the PC200W Campbell Software. Your screen will
look like Figure 7 below.
Figure 7: Main screen of PC200W software.
6. Connect the Data Logger to a Battery: Any battery that is 12 V DC can be used (e.g. a
car battery). Run two cables coming from the positive and negative poles of the battery
and connect them to the POWER IN12V and G notches in the data logger.
IMPORTANT: Connect the positive pole of the battery to the 12V notch in the data
logger and the negative pole to the G notch.